ABQ100CV1 / AZQS100B7V1B ABQ125CV1 / AZQS125B7V1B ABQ140CV1 / AZQS140B7V1B
Poff (Modo desligado) W 0.0    
Arrefecimento Psb (Arrefecimento no modo standby) W 9.0    
  Cooling-=-Cooling cdc degradation cooling 0.25    
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 9.50    
    Consumo anual de energia kWh 716    
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy label 4.65    
    Condição D (20℃ - 27/19) Pdc kW 4.20    
      potência nominal kW 0.58    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 7.35    
    Condição C (25℃ - 27/19) potência nominal kW 0.76    
      Pdc kW 4.50    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 5.94    
    Condição A (35°C - 27/19) potência nominal kW 3.63    
      Pdc kW 9.50    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 2.62    
    Condição B (30℃ - 27/19) Pdc kW 7.00    
      potência nominal kW 1.86    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 3.78    
  Aquecimento (Clima médio) Consumo anual de energia kWh 2,498    
    Pdesign kW 6.78    
    Tampa resist. apoio necessária em condições de design kW 3.89    
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop A    
    TBivalent Pdh (tampa resistência declarada) kW 6.00    
      Consumo kW 2.20    
      Tbiv (temperatura bivalente) °C -7    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.73    
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 3.00    
      Consumo kW 0.56    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.43    
    TOL Tol (temperatura-limite funcionamento) °C -15    
      Pdh (tampa de resistência declarada) kW 7.70    
      Consumo kW 4.33    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.78    
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 6.00    
      Consumo kW 2.20    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.73    
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 3.50    
      Consumo kW 0.55    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.45    
    Condição B (2℃) Consumo kW 1.05    
      Pdh (tampa de resist. declarada) kW 3.70    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.55    
Capacidade de arrefecimento Nom. kW 9.5 12.1 13.0
Pck (Modo aquecedor do cárter) W 0.0    
Eficiência nominal Consumo anual de energia kWh 1,813 2,153 (0.000) 2,159
  Diretiva de etiqueta da energia Aquecimento D   B
  Nominal efficiency-=-Cop 2.62 2.81 3.01
Aquecimento Psb (Aquecimento no modo standby) W 9.0    
  Heating-=-Heating cdh degradation heating 0.25    
Capacidade de aquecimento Nom. kW 10.8 13.5 15.5
Pto (Thermostat off) W 109.0    
Potência absorvida Arrefecimento Nom. kW 3.63 4.31 4.32
  Aquecimento Nom. kW 3.16 3.96 4.55
Estação fria incluída sim    
Notas Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal   Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal
Eficiência nominal Diretiva de etiqueta da energia Aquecimento   C  
Notas   EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE  
    Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal