D2U50GC015AB D2U50GC020AB D2U50GC024AB D2U50GC028AB D2U50GC015AA (Modelo anterior) D2U50GC020AA (Modelo anterior) D2U50GC024AA (Modelo anterior) D2U50GC028AA (Modelo anterior)
Número de aprovação CE CE-0063CR3574 CE-0063CR3574 CE-0063CR3574 CE-0063CR3574 CE-0063CR3574 CE-0063CR3574 CE-0063CR3574 CE-0063CR3574
Gás Categoria de dispositivos   C33, C43, C53, C63, C83, B23P, B33, B53, B53P, C13x, C33x, C43x, C53x, C63x, C83x, C93, C93x, C13, B23 C33, C43, C53, C63, C83, B23P, B33, B53, B53P, C13x, C33x, C43x, C53x, C63x, C83x, C93, C93x, C13, B23 C33, C43, C53, C63, C83, B23P, B33, B53, B53P, C13x, C33x, C43x, C53x, C63x, C83x, C93, C93x, C13, B23 C33, C43, C53, C63, C83, B23P, B33, B53, B53P, C13x, C33x, C43x, C53x, C63x, C83x, C93, C93x, C13, B23 C33, C43, C53, C63, C83, B23P, B33, B53, B53P, C13x, C33x, C43x, C53x, C63x, C83x, C93, C93x, C13, B23 C33, C43, C53, C63, C83, B23P, B33, B53, B53P, C13x, C33x, C43x, C53x, C63x, C83x, C93, C93x, C13, B23 C33, C43, C53, C63, C83, B23P, B33, B53, B53P, C13x, C33x, C43x, C53x, C63x, C83x, C93, C93x, C13, B23 C33, C43, C53, C63, C83, B23P, B33, B53, B53P, C13x, C33x, C43x, C53x, C63x, C83x, C93, C93x, C13, B23
  Pressão de alimentação Áustria   G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar)
    Bélgica   G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar)
    Croácia   G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar)
    Czech Republic   G20 (20 mbar) / G31 (50 mbar) G20 (20 mbar) / G31 (50 mbar) G20 (20 mbar) / G31 (50 mbar) G20 (20 mbar) / G31 (50 mbar) G20 (20 mbar) / G31 (50 mbar) G20 (20 mbar) / G31 (50 mbar) G20 (20 mbar) / G31 (50 mbar) G20 (20 mbar) / G31 (50 mbar)
    Dinamarca   G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar)
    Finlândia   G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar)
    France   G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar)
    Alemanha   G20 (20 mbar), G25 (25 mbar), G31 (50 mbar) G20 (20 mbar), G25 (25 mbar), G31 (50 mbar) G20 (20 mbar), G25 (25 mbar), G31 (50 mbar) G20 (20 mbar), G25 (25 mbar), G31 (50 mbar) G20 (20 mbar), G25 (25 mbar), G31 (50 mbar) G20 (20 mbar), G25 (25 mbar), G31 (50 mbar) G20 (20 mbar), G25 (25 mbar), G31 (50 mbar) G20 (20 mbar), G25 (25 mbar), G31 (50 mbar)
    Grécia   G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar)
    Hungria   G20(25 mbar), G31 (30 mbar) G20(25 mbar), G31 (30 mbar) G20(25 mbar), G31 (30 mbar) G20(25 mbar), G31 (30 mbar) G20(25 mbar), G31 (30 mbar) G20(25 mbar), G31 (30 mbar) G20(25 mbar), G31 (30 mbar) G20(25 mbar), G31 (30 mbar)
    Irlanda   G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar)
    Italy   G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar)
    Letónia   G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar)
    Lituânia   G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar)
    Luxemburgo   G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar)
    Netherlands   G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar)
    Noruega   G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar)
    Portugal   G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar)
    Eslováquia   G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar) G20 (20 mbar), G31 (50 mbar)
    Eslovénia   G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar)
    Espanha   G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar) G20 (20 mbar), G25 (25 mbar), G31 (37 mbar)
    Suécia   G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar)
    Suíça   G20 (20 mbar), G31 (37 mbar), G31 (50 mbar) G20 (20 mbar), G31 (37 mbar), G31 (50 mbar) G20 (20 mbar), G31 (37 mbar), G31 (50 mbar) G20 (20 mbar), G31 (37 mbar), G31 (50 mbar) G20 (20 mbar), G31 (37 mbar), G31 (50 mbar) G20 (20 mbar), G31 (37 mbar), G31 (50 mbar) G20 (20 mbar), G31 (37 mbar), G31 (50 mbar) G20 (20 mbar), G31 (37 mbar), G31 (50 mbar)
    Turquia   G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar) G20 (20 mbar)
    Reino Unido   G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar) G20 (20 mbar), G31 (37 mbar)
  Categoria Áustria   II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P
    Belgium   I2E(S), I3P, II2E(s)3P I2E(S), I3P, II2E(s)3P I2E(S), I3P, II2E(s)3P I2E(S), I3P, II2E(s)3P I2E(S), I3P, II2E(s)3P I2E(S), I3P, II2E(s)3P I2E(S), I3P, II2E(s)3P I2E(S), I3P, II2E(s)3P
    Croácia   II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P
    República Checa   II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P
    Dinamarca   I2H I2H I2H I2H I2H I2H I2H I2H
    Finlândia   I2H I2H I2H I2H I2H I2H I2H I2H
    França   II2E+3P, II2Er3P, II2H3P, II2N3P II2E+3P, II2Er3P, II2H3P, II2N3P II2E+3P, II2Er3P, II2H3P, II2N3P II2E+3P, II2Er3P, II2H3P, II2N3P II2E+3P, II2Er3P, II2H3P, II2N3P II2E+3P, II2Er3P, II2H3P, II2N3P II2E+3P, II2Er3P, II2H3P, II2N3P II2E+3P, II2Er3P, II2H3P, II2N3P
    Alemanha   II2ELL3P, II2N3P II2ELL3P, II2N3P II2ELL3P, II2N3P II2ELL3P, II2N3P II2ELL3P, II2N3P II2ELL3P, II2N3P II2ELL3P, II2N3P II2ELL3P, II2N3P
    Grécia   II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P
    Hungria   I2H3P I2H3P I2H3P I2H3P I2H3P I2H3P I2H3P I2H3P
    Irlanda   II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P
    Itália   II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P
    Letónia   I2H I2H I2H I2H I2H I2H I2H I2H
    Lituânia   II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P
    Luxemburgo   I2E I2E I2E I2E I2E I2E I2E I2E
    Holanda   I2H I2H I2H I2H I2H I2H I2H I2H
    Noruega   I2H I2H I2H I2H I2H I2H I2H I2H
    Portugal   II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P
    Eslováquia   II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P
    Eslovénia   II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P
    Espanha   II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P II2H3P, II2N3P
    Suécia   I2H I2H I2H I2H I2H I2H I2H I2H
    Suíça   II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P
    Turquia   I2H I2H I2H I2H I2H I2H I2H I2H
    Reino Unido   II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P II2H3P
  Ligação Diâmetro mm 20 20 20 20 20 20 20 20
  Consumo (G20) Mín m³/h 0.32 0.32 0.42 0.42 0.32 0.32 0.42 0.42
    Máx. m³/h 1.59 2.11 2.54 2.96 1.59 2.11 2.54 2.96
  Consumo (G25) Mín m³/h 0.35 0.35 0.47 0.47 0.35 0.35 0.47 0.47
    Máx. m³/h 1.75 2.33 2.80 3.26 1.75 2.33 2.80 3.26
  Consumo (G31) Mín m³/h 0.16 0.16 0.27 0.27 0.16 0.16 0.27 0.27
    Máx. m³/h 0.62 0.82 0.98 1.15 0.62 0.82 0.98 1.15
  Classe NOx   6 6 6 6 6 6 6 6
  Nível de NOx (G20) mg/kWh 23 31 31 31 26 34 34 34
Aquecimento central Qn de entrada de calor (valor calorífico líquido) Nom Mín kW 3.0 3.0 4.0 4.0 3.0 3.0 4.0 4.0
      Máx. kW 15.0 20.0 24.0 28.0 15.0 20.0 24.0 28.0
  Qn de entrada de calor (valor calorífico bruto) Nom Mín kW 3.3 3.3 4.4 4.4 3.3 3.3 4.4 4.4
      Máx. kW 16.7 22.2 26.6 31.1 16.7 22.2 26.6 31.1
  Pn de saída a 80/60°C Mín kW 2.9 2.9 3.9 3.9 2.9 2.9 3.9 3.9
    Nom kW 14.6 19.5 23.4 27.2 14.6 19.5 23.4 27.2
  Pnc de saída a 50/30°C Mín kW 3.2 3.2 4.3 4.3 3.2 3.2 4.3 4.3
    Nom kW 15.7 20.9 25.0 29.1 15.7 20.9 25.0 29.1
  Predefinição Saída Nom kW 15 20 24 28 15 20 24 28
  Pressão de água (PMS) Máx. bar 3 3 3 3 3 3 3 3
  Temperatura da água Máx. °C 85 85 85 85 90 90 90 90
  Eficiência em carga máxima, entrada de calor Valor calorífico líquido % 98 97 97 97 98 97 97 97
    Valor calorífico bruto % 88 88 88 87 88 88 88 87
  Eficiência em carga parcial, 30% Qa Valor calorífico líquido % 107 108 108 108 107 108 108 108
    Valor calorífico bruto % 97 97 97 97 97 97 97 97
  Intervalo de funcionamento Min °C 10 10 10 10 10 10 10 10
    Máx °C 85 85 85 85 90 90 90 90
Água quente sanitária Qnw de entrada de calor (valor calorífico líquido) Nom Mín kW 3.0 3.0 4.0 4.0 3.0 3.0 4.0 4.0
      Máx. kW 15.0 20.0 24.0 28.0 15.0 20.0 24.0 28.0
  Qnw de entrada de calor (valor calorífico bruto) Nom Mín kW 3.3 3.3 4.4 4.4 3.3 3.3 4.4 4.4
      Máx. kW 16.7 22.2 26.6 31.1 16.7 22.2 26.6 31.1
  Saída Mín kW 3.0 3.0 4.0 4.0 3.0 3.0 4.0 4.0
    Nom kW 15.0 20.0 24.0 28.0 15.0 20.0 24.0 28.0
    QD de saída contínua (DIN 4708) Nom kW 15.0 20.0 24.0 28.0 15.0 20.0 24.0 28.0
  Caudal de água Valor D (EN625) Nom l/min 23.0 24.0 25.0 26.0 23.0 24.0 25.0 26.0
    Velocidade de escoamento 10 min Máx. l/min 20.0 21.5 23.0 23.5 20.0 21.5 23.0 23.5
  Temperatura Máx. °C 70 70 70 70 85 85 85 85
    Predefinição °C 58 58 58 58 58 58 58 58
  Eficiência Características NL (DIN4708)   2.1 2.1 2.1 2.2 2.1 2.1 2.1 2.2
  Intervalo de funcionamento Min °C 10 10 10 10 10 10 10 10
    Máx °C 70 70 70 70 85 85 85 85
  Volume de água quente Com reaquecimento à velocidade de escoamento de 15 l/min l 370 500 600 900 370 500 600 900
    Sem reaquecimento à velocidade de escoamento de 15 l/min l 230 230 230 230 230 230 230 230
  Quantidade de água a curto prazo para QD l 200 215 230 235 200 215 230 235
Aquecimento de espaços Geral Prated kW 15 20 24 28 15 20 24 28
    P1 (Potência de aquecimento útil a 30% de potência de aquecimento nom. e regime de baixa temp) kW 4.8 6.5 7.8 9.1 4.8 6.5 7.8 9.1
    P4 (Potência de aquecimento útil em potência de aquecimento nominal e regime de alta temp) kW 14.6 19.5 23.4 27.2 14.6 19.5 23.4 27.2
    Ƞs (Eficiência de aquecimento ambiente sazonal) % 91 92 92 92 91 92 92 92
    Ƞ1 (Potência útil a 30% de potência de aquecimento nominal e regime de baixa temperatura) % 96.7 97.2 97.2 97.2 96.7 97.1 97.1 97.2
    Ƞ4 (Eficiência útil em potência de aquecimento nominal e regime de alta temperatura) % 87.4 87.7 88.0 88.0 87.3 87.7 87.9 87.9
    Classe de eficiência de aquecimento ambiente sazonal   A A A A A A A A
    Qhe Consumo energético anual (energia final) kWh 7,692 9,739 11,870 13,522 7,845 9,945 12,084 13,807
    Qhe Consumo energético anual (GCV) Gj 28 35 43 49 28 36 44 50
  Consumo de eletricidade auxiliar elmax (em plena carga) kW 0.036 0.038 0.038 0.038 0.036 0.038 0.038 0.038
    elmin (em carga parcial) kW 0.019 0.020 0.020 0.020 0.019 0.020 0.020 0.020
    Psb (Modo standby) kW 0.003 0.003 0.003 0.003 0.003 0.003 0.003 0.003
  Outro Emissões de NOx mg/kWh 23 31 31 31 23 31 31 31
    Ƞson (eficiência energética de aquecimento ambiente sazonal no modo ativo) % 95 96 96 96 95 96 96 96
    Pstby (perda de calor em standby) kW 0.047 0.047 0.047 0.047 0.047 0.047 0.047 0.047
Perdas de calor Perda de calor, perdas de inatividade térmica EN 15502-1         47 47 47 47
  Caldeira em espera kWh/24h         1.7 1.7 1.7 1.7
  Ps de caldeira em espera kW 0.0 0.0 0.0 0.0        
  qS de caldeira em espera kW 0.0 0.0 0.0 0.0        
Ar de alimentação Ligação mm 100 100 100 100 100 100 100 100
  Concêntrico   Sim Sim Sim Sim Sim Sim Sim Sim
Gás combustível Temperatura Máx. °C 63 69 64 68 63 69 64 68
  Ligação mm 60 60 60 60 60 60 60 60
  Comprimento DN60/100 Máx. m 10 15 14 10 10 15 14 10
  Comprimento DN80/125 Máx. m 7 11 14 15 7 11 14 15
  Caudal mássico (G20) Máx. kg/h 23.2 30.9 36.8 42.2 23.2 30.9 36.8 42.2
  Caudal mássico (G25) Máx. kg/h 22.2 29.7 35.3 40.5 22.2 29.7 35.3 40.5
  Caudal mássico (G31) Máx. kg/h 22.5 30.0 35.7 41.0 22.5 30.0 35.7 41.0
  Sobrepressão disponível Pa 170.0 200.0 185.0 200.0 170.0 200.0 185.0 200.0
  Tubo flexível de drenagem de condensados DN 32.0 32.0 32.0 32.0 32.0 32.0 32.0 32.0
Instalação_ Chão Chão Chão Chão Chão Chão Chão Chão
Estrutura Colour   Branco (RAL9016)/Cinzento escuro (RAL7011) Branco (RAL9016)/Cinzento escuro (RAL7011) Branco (RAL9016)/Cinzento escuro (RAL7011) Branco (RAL9016)/Cinzento escuro (RAL7011) Branco (RAL9016)/Cinzento escuro (RAL7011) Branco (RAL9016)/Cinzento escuro (RAL7011) Branco (RAL9016)/Cinzento escuro (RAL7011) Branco (RAL9016)/Cinzento escuro (RAL7011)
Dimensões Unidade Altura Estrutura mm 1,895 1,895 1,895 1,895 1,895 1,895 1,895 1,895
      Altura de instalação mínima mm 2,095.0 2,095.0 2,095.0 2,095.0 2,095.0 2,095.0 2,095.0 2,095.0
    Largura mm 790 790 790 790 790 790 790 790
    Profundidade mm 790 790 790 790 790 790 790 790
  Unidade embalada Altura mm 2,015 2,015 2,015 2,015 2,015 2,015 2,015 2,015
    Largura mm 800 800 800 800 800 800 800 800
    Profundidade mm 900 900 900 900 900 900 900 900
Peso Unidade Vazio kg 102 102 104 104 102 102 104 104
    Total kg 579 579 581 581 579 579 581 581
  Packed unit Empty kg 113 113 115 115 113 113 115 115
Acondicionamento Material   Placa ondulada, Película de acondicionamento PE Placa ondulada, Película de acondicionamento PE Placa ondulada, Película de acondicionamento PE Placa ondulada, Película de acondicionamento PE Placa ondulada, Película de acondicionamento PE Placa ondulada, Película de acondicionamento PE Placa ondulada, Película de acondicionamento PE Placa ondulada, Película de acondicionamento PE
  Peso kg 11 11 11 11 11 11 11 11
Caldeira Volume de água l 0.5 0.5 0.8 0.8 0.5 0.5 0.8 0.8
Tank Classe de eficiência energética   B B B B B B B B
  Psbsol W/K         1.6 1.6 1.6 1.6
  Perda de calor em standby W 72 72 72 72 71 71 71 71
  Volume de armazenamento l 477 477 477 477 477 477 477 477
  Volume de água l 477 477 477 477 500 500 500 500
  Material   Polipropileno Polipropileno Polipropileno Polipropileno Polipropileno Polipropileno Polipropileno Polipropileno
  Temperatura máxima da água °C 85.0 85.0 85.0 85.0 85 85 85 85
  Isolamento Material   Espuma de poliuretano sem HFC Espuma de poliuretano sem HFC Espuma de poliuretano sem HFC Espuma de poliuretano sem HFC Espuma de poliuretano Espuma de poliuretano Espuma de poliuretano Espuma de poliuretano
    Espessura mínima mm 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0
    Perda de calor kWh/24h 1.7 (1) 1.7 (1) 1.7 (1) 1.7 (1) 1.7 1.7 1.7 1.7
  Vbu (Solar, BUH) l 322 322 392 392 322 322 392 392
Permutador de calor Quantidade   2 2 2 2 2 2 2 2
  Água doméstica quente Quantidade   1 1 1 1 1 1 1 1
    Tube material   Stainless steel (1.4404) Stainless steel (1.4404) Stainless steel (1.4404) Stainless steel (1.4404) Stainless steel (1.4404) Stainless steel (1.4404) Stainless steel (1.4404) Stainless steel (1.4404)
    Área da face 4.900 4.900 4.900 4.900 5.000 5.000 5.000 5.000
    Volume da serpentina interna l 23.8 23.8 23.8 23.8 24.5 24.5 24.5 24.5
    Pressão de funcionamento bar 6 6 6 6 6 6 6 6
    Saída térmica específica média W/K 2,450 2,450 2,450 2,450 2,373 2,373 2,373 2,373
  Carregamento Quantidade   1 1 1 1 1 1 1 1
    Material de tubo   Aço inoxidável (DIN 1,4404) Aço inoxidável (DIN 1,4404) Aço inoxidável (DIN 1,4404) Aço inoxidável (DIN 1,4404) Aço inoxidável (DIN 1,4404) Aço inoxidável (DIN 1,4404) Aço inoxidável (DIN 1,4404) Aço inoxidável (DIN 1,4404)
    Área da face 2 2 4 4 2 2 4 4
    Volume da serpentina interna l 9 9 17 17 11 11 19 19
    Pressão de funcionamento bar 3 3 3 3 10 10 10 10
    Saída térmica específica média W/K 1,030 1,030 1,800 1,800        
  Solar pressurizado Quantidade   0 0 0 0 0 0 0 0
Válvula de 3 vias Modelo   Afriso USV Afriso USV Afriso USV Afriso USV Afriso USV Afriso USV Afriso USV Afriso USV
  Entrada polegada DN 25 (plug connection) DN 25 (plug connection) DN 25 (plug connection) DN 25 (plug connection) DN 25 (plug connection) DN 25 (plug connection) DN 25 (plug connection) DN 25 (plug connection)
  Saída Tipo polegada DN 25 (plug connection) DN 25 (plug connection) DN 25 (plug connection) DN 25 (plug connection) DN 25 (plug connection) DN 25 (plug connection) DN 25 (plug connection) DN 25 (plug connection)
  Tempo de trânsito seg 75.0 75.0 75.0 75.0 75.0 75.0 75.0 75.0
Motor do ventilador Modelo   ebmPapst NRG118/0800-3612-030203-V27.1 ebmPapst NRG118/0800-3612-030203-V27.1 ebmPapst NRG118/0800-3612-030203-V27.1 ebmPapst NRG118/0800-3612-030203-V27.1 ebmPapst NRG118/0800-3612-030203-V27.1 ebmPapst NRG118/0800-3612-030203-V27.1 ebmPapst NRG118/0800-3612-030203-V27.1 ebmPapst NRG118/0800-3612-030203-V27.1
Bomba Type   Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL Grundfos UPM3 25-75 CHBL Grundfos UPM3 25-75 CHBL RT Grundfos UPM3 25-75 CHBL RT Grundfos UPM3 25-75 CHBL RT
  Número de velocidades   Modulação Modulação Modulação Modulação Modulação Modulação Modulação Modulação
  Potência nominal W 60 60 60 60 60 60 60 60
  Altura máxima da bomba m 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5
Gas valve Type   Elster CES 10 (Lambda Gx) Elster CES 10 (Lambda Gx) Elster CES 10 (Lambda Gx) Elster CES 10 (Lambda Gx) Elster CES 10 (Lambda Gx) Elster CES 10 (Lambda Gx) Elster CES 10 (Lambda Gx) Elster CES 10 (Lambda Gx)
Circuito de água - Aquecimento central Diâmetro das tubagens polegada G 1 (macho) G 1 (macho) G 1 (macho) G 1 (macho) G 1" (fêmea) G 1" (fêmea) G 1" (fêmea) G 1" (fêmea)
  Pressão Aquecimento Máx. bar 3 3 3 3 3 3 3 3
  Válvula de segurança bar 3 3 3 3 1 1 1 1
  Válvula de purga de ar   Sim Sim Sim Sim Sim Sim Sim Sim
  Válvula de descarga/válvula de enchimento   Sim Sim Sim Sim Sim Sim Sim Sim
  Manometer   Digital Digital Digital Digital Digital Digital Digital Digital
Circuito de água - Lado da água quente sanitária Ligações de tubagens Entrada de água frente/Saída de água quente polegada G 1” (macho) G 1” (macho) G 1” (macho) G 1” (macho) G 1” (macho) G 1” (macho) G 1” (macho) G 1” (macho)
Local de instalação Interior Interior Interior Interior Interior Interior Interior Interior
Ligações de tubagens Solar collector inlet polegada G 1" (Female) G 1" (Female) G 1" (Female) G 1" (Female) G 1" (Female) G 1" (Female) G 1" (Female) G 1" (Female)
  Permutador de calor solar pressurizado polegada No No No No No No No No
  Entrada de água fria Diâmetro polegada G 1" (male) G 1" (male) G 1" (male) G 1" (male) G 1" (male) G 1" (male) G 1" (male) G 1" (male)
  Saída de água quente Diâmetro polegada G 1" (male) G 1" (male) G 1" (male) G 1" (male) G 1" (male) G 1" (male) G 1" (male) G 1" (male)
  polegada polegada G1" (male) G1" (male) G1" (male) G1" (male) G1" (female) G1" (female) G1" (female) G1" (female)
Sistemas de controlo Telecomando por infravermelhos   Gateway Rocon G1 Gateway Rocon G1 Gateway Rocon G1 Gateway Rocon G1 Gateway Rocon G1 Gateway Rocon G1 Gateway Rocon G1 Gateway Rocon G1
  Telecomando por cabo   room station Rocon U1 room station Rocon U1 room station Rocon U1 room station Rocon U1 room station Rocon U1 room station Rocon U1 room station Rocon U1 room station Rocon U1
  Classe de controlo da temperatura   A++ A++ A++ A++ A++ A++ A++ A++
  Contributo para a eficiência de aquecimento ambiente sazonal % 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0
Geral Detalhes do fornecedor/fabricante Nome e endereço   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Nome ou marca comercial   Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Descrição do produto Model identifier   GCU compact 515 GCU compact 520 GCU compact 524 GCU compact 528 GCU compact 515 GCU compact 520 GCU compact 524 GCU compact 528
    Caldeira de condensação   Sim Sim Sim Sim Sim Sim Sim Sim
    Caldeira de baixa temperatura   Não Não Não Não Não Não Não Não
    Caldeira B1   Não Não Não Não Não Não Não Não
    Aquecedor de ambiente de cogeração   Não Não Não Não Não Não Não Não
    Aquecedor de combinação   Sim Sim Sim Sim Sim Sim Sim Sim
    O aquecedor de combinação só funciona fora das horas de pico   Sim Sim Sim Sim Sim Sim Sim Sim
  LW(A) Nível da potência sonora (de acordo com EN14825) Interior dB(A) 53.0 58.0 61.0 64.0 53 55 56 56
  Aquecedor suplementar Tipo de entrada de energia   Gás Gás Gás Gás Gás Gás Gás Gás
Aquecimento de água quente sanitária Geral Perfil de carga declarado   XL XL XL XL XL XL XL XL
    Ƞwh (eficiência de aquecimento de água) % 84 82 84 84 89 82 82 82
    Qelec (consumo diário de eletricidade) kWh 0.466 0.510 0.460 0.463 0.250 0.260 0.340 0.290
    Qfuel (consumo diário de combustível) kWh 22.198 22.884 22.379 22.337 20.640 22.860 22.690 22.910
    Classe de eficiência energética de aquecimento de água   A A A A A A A A
    AEC (Consumo anual de eletricidade) kWh 39 35 34 36 27 27 45 33
    AFC (Consumo anual de combustível) Gj 17 17 17 17 16 18 18 18
    Qref (energia de referência do perfil de carga declarado) kWh 19.070 19.070 19.070 19.070 19.070 19.070 19.070 19.070
    Energia necessária para a geração de Qref kWh         19.760 19.570 19.690 19.630
Alimentação eléctrica Nome   V3 V3 V3 V3 V3 V3 V3 V3
  Fase   1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~
  Frequência Hz 50 50 50 50 50 50 50 50
  Tensão V 230 230 230 230 230 230 230 230
  Limite de tensão Mín. % 85 85 85 85 85 85 85 85
    Máx. % 110 110 110 110 110 110 110 110
Class IP   IP X0B IP X0B IP X0B IP X0B IP X0B IP X0B IP X0B IP X0B
  Válvula de 3 vias IP   IP54 IP54 IP54 IP54        
Consumo de energia elétrica Máx. W 76 98 104 108 76 98 104 108
  Standby W 3 3 3 3 3 3 3 3
Current Fusível Size A 6 6 6 6        
    Fase   1~ 1~ 1~ 1~        
    Pólo   1 1 1 1        
Sensor Sensor do depósito de armazenamento   NTC NTC NTC NTC NTC NTC NTC NTC
  Sensor de temperatura de retorno   NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm)
  Feed temperature sensor   NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm)
  Sensor do caudal   Frequency Frequência Frequency Frequency NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm)
  Ambient temperature sensor   NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm) NTC (10k Ohm)
Bomba Type   UPM3(K)25-75 UPM3(K)25-75 UPM3(K)25-75 UPM3(K)25-75        
Notes_Description 1 1 1 1