EHBH11CB3V / ERLQ011CAW1 EHBH11CB9W / ERLQ011CAW1 EHBH16CB3V / ERLQ014CAW1 EHBH16CB9W / ERLQ014CAW1 EHBH16CB3V / ERLQ016CAW1 EHBH16CB9W / ERLQ016CAW1
Capacidade de aquecimento Nom. kW 11.2 (1), 11.0 (2) 11.2 (1), 11.0 (2) 14.5 (1), 13.6 (2) 14.5 (1), 13.6 (2) 16.0 (1), 15.2 (2) 16.0 (1), 15.2 (2)
  Máx. kW 8.60 (3), 8.60 (4) 8.60 (3), 8.60 (4) 10.6 (3), 10.8 (4) 10.6 (3), 10.8 (4) 11.4 (3), 10.9 (4) 11.4 (3), 10.9 (4)
Potência absorvida Aquecimento Nom. kW 3.42 (1), 4.21 (2) 3.42 (1), 4.21 (2) 3.37 (1), 4.10 (2) 3.37 (1), 4.10 (2) 3.76 (1), 4.66 (2) 3.76 (1), 4.66 (2)
    Máx. kW 3.13 (3), 4.10 (4) 3.13 (3), 4.10 (4) 4.00 (3), 5.19 (4) 4.00 (3), 5.19 (4) 4.32 (3), 5.22 (4) 4.32 (3), 5.22 (4)
COP 4.60 (1), 2.75 (3), 3.55 (2), 2.10 (4) 4.60 (1), 2.75 (3), 3.55 (2), 2.10 (4) 4.30 (1), 2.65 (3), 3.32 (2), 2.08 (4) 4.30 (1), 2.65 (3), 3.32 (2), 2.08 (4) 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4) 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4)
Bomba Unidade ESP nominal Aquecimento kPa 37.0 (7), 39.0 (8) 37.0 (7), 39.0 (8) 49.0 (7), 57.0 (8) 49.0 (7), 57.0 (8) 33.0 (7), 42.0 (8) 33.0 (7), 42.0 (8)
Permutador de calor lado da água Caudal de água Aquecimento Nom. l/min 32.1 (7), 31.5 (8) 32.1 (7), 31.5 (8) 41.6 (7), 39.0 (8) 41.6 (7), 39.0 (8) 45.9 (7), 43.6 (8) 45.9 (7), 43.6 (8)
Geral Detalhes do fornecedor/fabricante Nome e endereço   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Nome ou marca comercial   Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Descrição do produto Bomba de calor ar-água   Sim Sim Sim Sim Sim Sim
    Bomba de calor de glicol-para-água   Não Não Não Não Não Não
    Combinação de bomba de calor e resistência   Não Não Não Não Não Não
    Bomba de calor de baixa temperatura   Não Não Não Não Não Não
    Aquecedor suplementar integrado   Sim Sim Sim Sim Sim Sim
    Bomba de calor água-água   Não Não Não Não Não Não
  LW(A) Nível da potência sonora (de acordo com EN14825) Interior dB(A) 41.0 41.0 44.0 44.0 44.0 44.0
Nível de potência sonora LW(A) (de acordo com EN14825) Exterior dB(A) 64.0 64.0 64.0 64.0 66.0 66.0
Condição sonora Ecodesign e etiqueta energética Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825 Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825 Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825 Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825 Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825 Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825
Aquecimento de espaços geral Unidade ar-água Caudal de ar nominal (exterior) m³/h 5,400 5,400 5,400 5,400 5,400 5,400
  Outro Controlo de capacidade   Inverter Inverter Inverter Inverter Inverter Inverter
    Cdh (Degradação de aquecimento)   1.00 1.00 1.00 1.00 1.00 1.00
    Pck (Modo de resistência do cárter) kW 0.055 0.055 0.055 0.055 0.055 0.055
    Poff (Modo desligado) kW 0.055 0.055 0.055 0.055 0.055 0.055
    Psb (modo standby) kW 0.055 0.055 0.055 0.055 0.055 0.055
    Pto (Termóstato desligado) kW 0.057 0.057 0.057 0.057 0.057 0.057
  Resistência suplementar integrada Emissão de NOx mg/kWh 0.00 0.00 0.00 0.00 0.00 0.00
    Psup kW 3.00 9.00 3.00 9.00 3.00 9.00
    Tipo de entrada de energia   Elétrico Elétrico Elétrico Elétrico Elétrico Elétrico
Aquecimento de espaços Clima médio, saída da água 55 °C Geral Consumo anual de energia kWh 6,260 6,260 7,900 7,900 8,970 8,970
      Eficiência sazonal de aquecimento de espaços % 120 120 123 123 119 119
      A -10 °C kW 9.99 9.99 12.7 12.7 13.9 13.9
      Consumo anual de energia Qhe (GCV) Gj 22.6 22.6 28.4 28.4 32.3 32.3
      SCOP   3.09 3.09 3.16 3.16 3.06 3.06
      Classe de efic. sazonal de aquecimento de espaços   A+ A+ A+ A+ A+ A+
    Condição A (-7 °CBs/-8 °CBh) Cdh (Degradação de aquecimento)   1.00 1.00 1.00 1.00 1.00 1.00
      COPd   1.99 1.99 1.76 1.76 1.78 1.78
      Pdh kW 8.83 8.83 9.97 9.97 12.2 12.2
      PERd % 79.6 79.6 70.4 70.4 71.2 71.2
    Condição B (2° CBs/1° CBh) Cdh (Degradação de aquecimento)   1.00 1.00 1.00 1.00 1.00 1.00
      COPd   3.24 3.24 3.55 3.55 3.12 3.12
      Pdh kW 5.28 5.28 6.76 6.76 7.61 7.61
      PERd % 130 130 142 142 125 125
    Condição C (7 °CBs/6 °CBh) Cdh (Degradação de aquecimento)   0.950 0.950 0.950 0.950 1.00 1.00
      COPd   4.31 4.31 4.22 4.22 4.40 4.40
      Pdh kW 4.47 4.47 4.66 4.66 4.83 4.83
      PERd % 172 172 169 169 176 176
    Condição D (12° CBs/11° CBh) Cdh (Degradação de aquecimento)   0.930 0.930 0.940 0.940 0.930 0.930
      COPd   6.41 6.41 5.44 5.44 6.36 6.36
      Pdh kW 5.37 5.37 5.26 5.26 5.38 5.38
      PERd % 256 256 218 218 254 254
    Tol (temperatura-limite de funcionamento) COPd   1.79 1.79 1.75 1.75 1.71 1.71
      Pdh kW 9.08 9.08 12.2 12.2 13.3 13.3
      PERd % 71.6 71.6 70.0 70.0 68.4 68.4
      TOL °C -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      WTOL °C 55.0 55.0 55.0 55.0 55.0 55.0
    Capac. potência calorífica nom. supl. Psup (a Tdesign -10 °C) kW 0.910 0.910 0.550 0.550 0.580 0.580
    Tbiv (temperatura bivalente) COPd   1.99 1.99 1.92 1.92 1.78 1.78
      Pdh kW 8.83 8.83 11.0 11.0 12.2 12.2
      PERd % 79.6 79.6 76.8 76.8 71.2 71.2
      Tbiv °C -7.00 -7.00 -6.00 -6.00 -7.00 -7.00
  Clima frio, saída da água 55 °C Geral Consumo anual de energia kWh 6,740 6,740 7,870 7,870 8,580 8,580
      Eficiência sazonal de aquecimento de espaços % 95.0 95.0 95.5 95.5 98.3 98.3
      A -22°C kW 6.99 6.99 8.15 8.15 9.12 9.12
      Consumo anual de energia Qhe (GCV) Gj 24.3 24.3 28.3 28.3 30.9 30.9
  Clima quente, saída de água 55 °C Geral Consumo anual de energia kWh 2,630 2,630 3,270 3,270 3,420 3,420
      Ƞs (Eficiência sazonal de aquecimento de espaços) % 125 125 135 135 136 136
      A 2°C kW 7.58 7.58 9.84 9.84 10.3 10.3
      Consumo anual de energia Qhe (GCV) Gj 9.47 9.47 11.8 11.8 12.3 12.3
  Clima médio, saída da água 35 °C Geral SCOP   3.98 3.98 3.90 3.90 3.80 3.80
      Consumo anual de energia kWh 5,380 5,380 7,250 7,250 8,270 8,270
      Ƞs (Eficiência sazonal de aquecimento de espaços) % 156 156 153 153 149 149
      A -10°C kW 11.2 11.2 14.5 14.5 16.0 16.0
      Consumo anual de energia Qhe (GCV) Gj 19.4 19.4 26.1 26.1 29.8 29.8
      Classe de efic. sazonal de aquecimento de espaços   A++ A++ A++ A++ A+ A+
    Condição A (-7° CBs/-8° CBh) COPd   2.63 2.63 2.63 2.63 2.33 2.33
      Pdh kW 8.88 8.88 10.7 10.7 12.4 12.4
      PERd % 105 105 105 105 93.2 93.2
    Condição B (2 °CBs/1 °CBh) Cdh (Degradação de aquecimento)   1.00 1.00 1.00 1.00 1.00 1.00
      COPd   4.05 4.05 4.07 4.07 3.74 3.74
      Pdh kW 6.03 6.03 7.71 7.71 8.62 8.62
      PERd % 162 162 163 163 150 150
    Condição C (7° CBs/6° CBh) Cdh (Degradação de aquecimento)   0.940 0.940 1.00 1.00 0.940 0.940
      COPd   6.77 6.77 5.71 5.71 6.77 6.77
      Pdh kW 5.74 5.74 5.05 5.05 5.74 5.74
      PERd % 271 271 228 228 271 271
    Condição D (12 °CBs/11 °CBh) Cdh (Aquecimento de degradação)   0.920 0.920 0.930 0.930 0.920 0.920
      COPd   8.97 8.97 6.71 6.71 8.97 8.97
      Pdh kW 6.50 6.50 5.16 5.16 6.50 6.50
      PERd % 359 359 268 268 359 359
    Tol (temperatura-limite de funcionamento) COPd   2.34 2.34 2.60 2.60 2.05 2.05
      Pdh kW 8.76 8.76 12.6 12.6 11.7 11.7
      PERd % 93.6 93.6 104 104 82.0 82.0
      TOL °C -10.0 -10.0 -10.0 -10.0 -10.0 -10.0
      WTOL °C 35.0 35.0 35.0 35.0 35.0 35.0
    Tbiv (temperatura bivalente) COPd   2.82 2.82 2.83 2.83 2.56 2.56
      Pdh kW 9.09 9.09 11.6 11.6 12.1 12.1
      PERd % 113 113 113 113 102 102
      Tbiv °C -5.00 -5.00 -5.00 -5.00 -4.00 -4.00
    Capacidade suplementar pot. calorífica nominal Psup (a Tdesign -10 °C) kW 2.44 2.44 1.93 1.93 4.35 4.35
  Clima frio, saída da água 35 °C Geral Consumo anual de energia kWh 6,430 6,430 8,170 8,170 9,050 9,050
      Ƞs (Eficiência sazonal de aquecimento de espaços) % 148 148 141 141 137 137
      A -22°C kW 10.3 10.3 12.3 12.3 13.3 13.3
      Consumo anual de energia Qhe (GCV) Gj 23.1 23.1 29.4 29.4 32.6 32.6
  Clima quente, saída de água 35°C Geral Consumo anual de energia kWh 1,950 1,950 2,350 2,350 2,480 2,480
      Ƞs (Eficiência sazonal de aquecimento de espaços) % 192 192 199 199 199 199
      A 2°C kW 9.06 9.06 10.9 10.9 11.4 11.4
      Consumo anual de energia Qhe (GCV) Gj 7.02 7.02 8.46 8.46 8.92 8.92
Notas (1) - Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C)
  (3) - Condição 3: aquecimento Ta DB -7°C (RH85%) - LWC 35°C (3) - Condição 3: aquecimento Ta DB -7°C (RH85%) - LWC 35°C (3) - Condição 3: aquecimento Ta DB -7°C (RH85%) - LWC 35°C (3) - Condição 3: aquecimento Ta DB -7°C (RH85%) - LWC 35°C (3) - Condição 3: aquecimento Ta DB -7°C (RH85%) - LWC 35°C (3) - Condição 3: aquecimento Ta DB -7°C (RH85%) - LWC 35°C
  (4) - Condição 4: aquecimento Ta DB -7°C (RH85%) - LWC 45℃ (4) - Condição 4: aquecimento Ta DB -7°C (RH85%) - LWC 45℃ (4) - Condição 4: aquecimento Ta DB -7°C (RH85%) - LWC 45℃ (4) - Condição 4: aquecimento Ta DB -7°C (RH85%) - LWC 45℃ (4) - Condição 4: aquecimento Ta DB -7°C (RH85%) - LWC 45℃ (4) - Condição 4: aquecimento Ta DB -7°C (RH85%) - LWC 45℃
  (5) - Tamb 35°C - LWE 7°C (DT=5°C) (5) - Tamb 35°C - LWE 7°C (DT=5°C) (5) - Tamb 35°C - LWE 7°C (DT=5°C) (5) - Tamb 35°C - LWE 7°C (DT=5°C) (5) - Tamb 35°C - LWE 7°C (DT=5°C) (5) - Tamb 35°C - LWE 7°C (DT=5°C)
  (6) - Tamb 35°C - LWE 18℃ (DT=5°C) (6) - Tamb 35°C - LWE 18℃ (DT=5°C) (6) - Tamb 35°C - LWE 18℃ (DT=5°C) (6) - Tamb 35°C - LWE 18℃ (DT=5°C) (6) - Tamb 35°C - LWE 18℃ (DT=5°C) (6) - Tamb 35°C - LWE 18℃ (DT=5°C)
  (7) - Bs/Bh 7°C/6°C-LWC 35°C(DT=5°C) (7) - Bs/Bh 7°C/6°C-LWC 35°C(DT=5°C) (7) - Bs/Bh 7°C/6°C-LWC 35°C(DT=5°C) (7) - Bs/Bh 7°C/6°C-LWC 35°C(DT=5°C) (7) - Bs/Bh 7°C/6°C-LWC 35°C(DT=5°C) (7) - Bs/Bh 7°C/6°C-LWC 35°C(DT=5°C)
  (8) - DB/WB 7°C/6°C - LWC 45℃ (Dt=5°C) (8) - DB/WB 7°C/6°C - LWC 45℃ (Dt=5°C) (8) - DB/WB 7°C/6°C - LWC 45℃ (Dt=5°C) (8) - DB/WB 7°C/6°C - LWC 45℃ (Dt=5°C) (8) - DB/WB 7°C/6°C - LWC 45℃ (Dt=5°C) (8) - DB/WB 7°C/6°C - LWC 45℃ (Dt=5°C)