EHSH04P30DA / ERGA04DAV3 EHSH08P30DA / ERGA06DAV3A EHSH08P50DA / ERGA06DAV3A EHSH08P50DA / ERGA06DAV3 EHSH08P30DA / ERGA06DAV3 EHSH08P50DA / ERGA08DAV3A EHSH08P30DA / ERGA08DAV3A EHSH08P30DA / ERGA08DAV3 EHSH08P50DA / ERGA08DAV3
Unidade interior EHSH04P30D EHSH08P30D EHSH08P50D EHSH08P50D EHSH08P30D EHSH08P50D EHSH08P30D EHSH08P30D EHSH08P50D
Unidade exterior ERGA04DAV3 ERGA06DAV3A ERGA06DAV3A ERGA06DAV3 ERGA06DAV3 ERGA08DAV3A ERGA08DAV3A ERGA08DAV3 ERGA08DAV3
Capacidade de aquecimento Nom. kW 4.30 (1), 4.60 (2) 5.90 (2), 6.00 (1) 5.90 (2), 6.00 (1) 6.00 (1), 5.90 (2) 6.00 (1), 5.90 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2)
Potência absorvida Aquecimento Nom. kW 0.850 (1), 1.26 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2)
Heat up time from 10°C to 50°C hr 1h31min     2h57min 1h31min     1h31min 2h57min
COP 5.10 (1), 3.65 (2) 3.50 (2), 4.85 (1) 3.50 (2), 4.85 (1) 4.85 (1), 3.50 (2) 4.85 (1), 3.50 (2) 3.50 (2), 4.60 (1) 3.50 (2), 4.60 (1) 4.60 (1), 3.50 (2) 4.60 (1), 3.50 (2)
Bomba Type   Grundfos UPM3K 25-75 CHBL     Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL     Grundfos UPM3K 25-75 CHBL Grundfos UPM3K 25-75 CHBL
  Unidade ESP nominal Aquecimento kPa 66.0 (1), 65.0 (2) 57.4 (1), 58.1 (2) 57.4 (1), 58.1 (2) 57.4 (1), 58.1 (2) 57.4 (1), 58.1 (2) 38.7 (2), 42.7 (1) 38.7 (2), 42.7 (1) 42.7 (1), 38.7 (2) 42.7 (1), 38.7 (2)
Permutador de calor lado da água Caudal de água Aquecimento Nom. l/min 12.3 (1), 13.2 (2) 16.9 (2), 17.2 (1) 16.9 (2), 17.2 (1) 17.2 (1), 16.9 (2) 17.2 (1), 16.9 (2) 21.5 (1), 22.4 (2) 21.5 (1), 22.4 (2) 21.5 (1), 22.4 (2) 21.5 (1), 22.4 (2)
Geral Descrição do produto Bomba de calor ar-água   Sim Sim Sim Sim Sim Sim Sim Sim Sim
    Bomba de calor de glicol-para-água   Não Não Não Não Não Não Não Não Não
    Combinação de bomba de calor e resistência   Sim Sim Sim Sim Sim Sim Sim Sim Sim
    Bomba de calor de baixa temperatura   Não Não Não Não Não Não Não Não Não
    Aquecedor suplementar integrado   Não Não Não Não Não Não Não Não Não
    Bomba de calor água-água   Não Não Não Não Não Não Não Não Não
  LW(A) Nível da potência sonora (de acordo com EN14825) Interior dB(A) 39 39 39 39 39 39 39 39 39
Nível de potência sonora LW(A) (de acordo com EN14825) Exterior dB(A) 58 60 60 60 60 62 62 62 62
Condição sonora Ecodesign e etiqueta energética Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825 Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825 Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825 Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825 Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825 Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825 Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825 Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825 Potência sonora no modo de aquecimento, medido em conformidade com a EN12102 sob as condições da EN14825
Aquecimento de espaços geral Unidade ar-água Caudal de ar nominal (exterior) m³/h 2,280 27,770 27,770 2,520 2,520 2,770 2,770 2,770 2,770
  Outro Controlo de capacidade   Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter Inverter
    Poff (Modo desligado) kW 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010
    Psb (modo standby) kW 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010
    Pto (Termóstato desligado) kW 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010
  Resistência suplementar integrada Tipo de entrada de energia   Elétrico Elétrico Elétrico Elétrico Elétrico Elétrico Elétrico Elétrico Elétrico
Aquecimento de água quente sanitária Geral Perfil de carga declarado   L L XL XL L XL L L XL
    Função para fixar o aquecimento de água durante as horas que não as de pico   Sim Sim Sim Sim Sim Sim Sim Sim Sim
  Clima médio AEC (consumo de eletricidade anual) kWh 951 1,074 1,715 1,584 951 1,715 1,074 951 1,584
    Ƞwh (eficiência de aquecimento de água) % 108 95 98 106 108 98 95 108 106
    Qelec (consumo de eletricidade diário) kWh 4.500 5.128 8.037 7.426 4.500 8.037 5.128 4.500 7.426
    Classe de eficiência energética para aquecimento de água   A A   A A   A A A
  Clima frio AEC (consumo de eletricidade anual) kWh 1,366 1,366 2,260 2,260 1,366 2,260 1,366 1,366 2,260
    Ƞwh (eficiência de aquecimento de água) % 75 75 75 75 75 75 75 75 75
    Qelec (consumo de eletricidade diário) kWh 6.454 6.454 10.520 10.520 6.454 10.520 6.454 6.454 10.520
  Clima quente AEC (consumo de eletricidade anual) kWh 940 940 1,436 1,436 940 1,436 940 940 1,436
    Ƞwh (eficiência de aquecimento de água) % 109 109 117 117 109 117 109 109 117
    Qelec (consumo de eletricidade diário) kWh 4.513 4.513 6.766 6.766 4.513 6.766 4.513 4.513 6.766
Aquecimento de espaços Clima médio, saída da água 55 °C Geral SCOP   3.26 3.25 3.25 3.26 3.26 3.27 3.27 3.32 3.32
      Consumo anual de energia kWh 3,806 4,456 4,456 4,441 4,441 4,731 4,731 4,975 4,975
      Eficiência sazonal de aquecimento de espaços % 127 127 127 127 127 128 128 130 130
      A -10 °C kW 6.0 7 7 7.0 7.0 8 8 8.0 8.0
      Classe de efic. sazonal de aquecimento de espaços   A++ A++ A++ A++ A++ A++ A++ A++ A++
    Condição A (-7 °CBs/-8 °CBh) Cdh (Degradação de aquecimento)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   1.97 1.98 1.98 1.98 1.98 198.00 198.00 1.96 1.96
      Pdh kW 5.3 5.9 5.9 5.9 5.9 5.9 5.9 6.9 6.9
      PERd % 79.0 79.0 79.0 79.0 79.0 79.0 79.0 78.0 78.0
    Condição B (2° CBs/1° CBh) Cdh (Degradação de aquecimento)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.23 3.16 3.16 3.16 3.16 3.18 3.18 3.20 3.20
      Pdh kW 3.3 3.9 3.9 3.9 3.9 4.1 4.1 4.4 4.4
      PERd % 129.0 126.0 126.0 126.0 126.0 127.0 127.0 128.0 128.0
    Condição C (7 °CBs/6 °CBh) Cdh (Degradação de aquecimento)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.40 4.49 4.49 4.49 4.49 4.54 4.54 4.64 4.64
      Pdh kW 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.3 3.3
      PERd % 176.0 180.0 180.0 180.0 180.0 182.0 182.0 186.0 186.0
    Condição D (12° CBs/11° CBh) Cdh (Degradação de aquecimento)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.10 6.10 6.10 6.10 6.10 6.16 6.16 6.22 6.22
      Pdh kW 3.3 3.3 3.3 3.3 3.3 3.7 3.7 4.1 4.1
      PERd % 244.0 244.0 244.0 244.0 244.0 246.0 246.0 249.0 249.0
    Tol (temperatura-limite de funcionamento) COPd   1.37 1.43 1.43 1.53 1.53 1.43 1.43 1.64 1.64
      Pdh kW 4.0 4.5 4.5 5.4 5.4 4.5 4.5 7.1 7.1
      PERd % 55.0 57.0 57.0 61.0 61.0 57.0 57.0 66.0 66.0
      TOL °C -10 -10 -10 -10 -10 -10 -10 -10 -10
      WTOL °C 55 55 55 55 55 55 55 55 55
    Tbiv (temperatura bivalente) COPd   1.97 2.12 2.12 2.12 2.12 2.18 2.18 1.90 1.90
      Pdh kW 5.3 6.1 6.1 6.1 6.1 6.4 6.4 7.5 7.5
      PERd % 79.0 85.0 85.0 85.0 85.0 87.0 87.0 76.0 76.0
      Tbiv °C -7 -6 -6 -6 -6 -6 -6 -8 -8
  Clima frio, saída da água 55 °C Geral Consumo anual de energia kWh 4,468 5,325 5,325 5,300 5,300 7,066 7,066 6,886 6,886
      Eficiência sazonal de aquecimento de espaços % 107 108 108 109 109 109 109 112 112
      A -22°C kW 5 6 6 6 6 8 8 8 8
  Clima quente, saída de água 55 °C Geral Consumo anual de energia kWh 1,660 1,858 1,858 1,858 1,858 1,983 1,983 2,213 2,213
      Ƞs (Eficiência sazonal de aquecimento de espaços) % 148 158 158 158 158 159 159 161 161
      A 2°C kW 5 6 6 6 6 6 6 7 7
  Clima médio, saída da água 35 °C Geral SCOP   4.48 4.47 4.47 4.47 4.47 4.56 4.56 4.56 4.56
      Consumo anual de energia kWh 2,766 3,233 3,233 3,233 3,233 3,625 3,625 3,625 3,625
      Ƞs (Eficiência sazonal de aquecimento de espaços) % 176 176 176 176 176 179 179 179 179
      A -10°C kW 6.0 7 7 7.0 7.0 8 8 8.0 8.0
      Consumo anual de energia Qhe (GCV) Gj 1 1 1 1 1 1 1 1 1
      Classe de efic. sazonal de aquecimento de espaços   A++ A++ A++ A++ A++ A++ A++ A++ A++
    Condição A (-7° CBs/-8° CBh) COPd   2.90 2.86 2.86 2.86 2.86 2.77 2.77 2.77 2.77
      Pdh kW 5.5 6.0 6.0 6.0 6.0 7.0 7.0 7.0 7.0
      PERd % 116.0 114.0 114.0 114.0 114.0 111.0 111.0 111.0 111.0
    Condição B (2 °CBs/1 °CBh) Cdh (Degradação de aquecimento)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.33 4.25 4.25 4.25 4.25 4.35 4.35 4.35 4.35
      Pdh kW 3.3 3.9 3.9 3.9 3.9 4.2 4.2 4.2 4.2
      PERd % 173.0 170.0 170.0 170.0 170.0 174.0 174.0 174.0 174.0
    Condição C (7° CBs/6° CBh) Cdh (Degradação de aquecimento)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.19 6.30 6.30 6.30 6.30 6.49 6.49 6.49 6.49
      Pdh kW 3.2 3.2 3.2 3.2 3.2 3.3 3.3 3.3 3.3
      PERd % 248.0 252.0 252.0 252.0 252.0 260.0 260.0 260.0 260.0
    Condição D (12 °CBs/11 °CBh) Cdh (Aquecimento de degradação)   1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.78 7.78 7.78 7.78 7.78 8.52 8.52 8.52 8.52
      Pdh kW 3.3 3.3 3.3 3.3 3.3 3.9 3.9 3.9 3.9
      PERd % 311.0 311.0 311.0 311.0 311.0 341.0 341.0 341.0 341.0
    Tol (temperatura-limite de funcionamento) COPd   2.56 2.49 2.49 2.49 2.49 2.41 2.41 2.41 2.41
      Pdh kW 5.2 6.0 6.0 6.0 6.0 6.9 6.9 6.9 6.9
      PERd % 102.0 100.0 100.0 100.0 100.0 96.0 96.0 96.0 96.0
      TOL °C -10 -10 -10 -10 -10 -10 -10 -10 -10
      WTOL °C 35 35 35 35 35 35 35 35 35
    Tbiv (temperatura bivalente) COPd   2.90 3.07 3.07 2.49 2.49 2.66 2.66 2.66 2.66
      Pdh kW 5.5 6.1 6.1 6.0 6.0 7.5 7.5 7.5 7.5
      PERd % 116.0 123.0 123.0 100.0 100.0 106.0 106.0 106.0 106.0
      Tbiv °C -7 -6 -6 -6 -6 -8 -8 -8 -8
    Capacidade suplementar pot. calorífica nominal Psup (a Tdesign -10 °C) kW 0.8                
  Clima frio, saída da água 35 °C Geral Consumo anual de energia kWh 3,230 3,749 3,749 3,749 3,749 5,052 5,052 5,034 5,034
      Ƞs (Eficiência sazonal de aquecimento de espaços) % 150 155 155 155 155 153 153 154 154
      A -22°C kW 5 6 6 6 6 8 8 8 8
  Clima quente, saída de água 35°C Geral Consumo anual de energia kWh 1,139 1,276 1,276 1,276 1,276   1,437 1,437 1,437
      Ƞs (Eficiência sazonal de aquecimento de espaços) % 241 248 248 248 248   257 257 257
      A 2°C kW 5 6 6 6 6   7 7 7
Notas Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Condição 1: arrefecimento Ta 35°C - LWE 18℃ (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Condição 2: arrefecimento Ta 35°C - LWE 7°C (DT = 5°C); aquecimento Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C)