FCAHG71FVEB / RZAG71L7V1B FCAHG100FVEB / RZAG100L7V1B FCAHG125FVEB / RZAG125L7V1B FCAHG140FVEB / RZAG140L7V1 FCAHG140FVEB / RZAG140L7V1B
Poff (Modo desligado) W 0.0 0.0 0.0    
Arrefecimento Psb (Arrefecimento no modo standby) W 9.0 10.0 10.0    
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25    
Eurovent Nível de potência sonora no interior Arrefecimento Nom. dBA 53 61 61    
  Sound power level outdoor Cooling Nom. dBA 64 64 66    
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 6.80 9.50 12.00    
    Consumo anual de energia kWh 324 452 605    
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 7.35 (2) 7.35 (2) 6.94 (2)    
    Condição D (20℃ - 27/19) Pdc kW 3.38 3.60 2.60    
      potência nominal kW 0.28 0.27 0.27    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 12.10 13.15 9.80    
    Condição C (25℃ - 27/19) potência nominal kW 0.38 0.57 0.69    
      Pdc kW 3.57 4.70 5.80    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 9.30 8.25 8.40    
    Condição A (35°C - 27/19) potência nominal kW 1.55 2.06 2.93    
      Pdc kW 6.80 9.50 12.00    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.38 4.61 4.10    
    Condição B (30℃ - 27/19) Pdc kW 5.01 7.00 8.90    
      potência nominal kW 0.82 1.18 1.65    
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.12 5.95 5.40    
  Aquecimento (Clima médio) Consumo anual de energia kWh 1,743 2,753 2,879    
    Capacidade de aquecimento Pdh a -10° kW 5.45 8.27 9.31    
    Pdesign kW 5.65 9.13 9.52    
    Tampa resist. apoio necessária em condições de design kW 0.21 0.86 0.21    
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+ A++ A++    
    TBivalent Pdh (tampa resistência declarada) kW 5.00 8.08 8.42    
      Consumo kW 2.00 2.76 2.95    
      Tbiv (temperatura bivalente) °C -7 -7 -7    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.50 2.93 2.85    
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 2.63 4.38 3.95    
      Consumo kW 0.41 0.72 0.66    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.41 6.12 5.97    
    TOL Tol (temperatura-limite funcionamento) °C -15 -15 -15    
      Pdh (tampa de resistência declarada) kW 6.19 8.60 10.80    
      Consumo kW 3.02 4.07 5.78    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.05 2.11 1.87    
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 5.00 8.08 8.42    
      Consumo kW 2.00 2.76 2.95    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.50 2.93 2.85    
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 2.77 4.85 4.20    
      Consumo kW 0.37 0.64 0.56    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.39 7.57 7.50    
    Condição B (2℃) Consumo kW 0.65 1.06 1.08    
      Pdh (tampa de resist. declarada) kW 3.04 5.06 5.13    
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.70 4.76 4.74    
Capacidade de arrefecimento Nom. kW 6.8 9.5 12.0 13.4 13.4
Pck (Modo aquecedor do cárter) W 0.0 0.0 0.0    
Eficiência nominal Consumo anual de energia kWh 830 (0.000) 1,075 (0.000) 1,500 (0.000) 2,000 2,000 (0.000)
  Diretiva de etiqueta da energia Aquecimento A A A   A
  Nominal efficiency-=-Cop 4.09 4.42 4.00 3.35 3.35
Aquecimento Psb (Aquecimento no modo standby) W 9.0 10.0 10.0    
  Heating-=-Heating cdh degradation heating 0.25 0.25 0.25    
Capacidade de aquecimento Nom. kW 7.5 10.8 13.5 15.5 15.5
Pto (Thermostat off) W 8.0 11.0 11.0    
Potência absorvida Arrefecimento Nom. kW 1.66 2.15 3.00 4.00 4.00
  Aquecimento Nom. kW 1.56 2.16 3.07 3.77 3.77
Estação fria incluída Sim Sim Sim    
Notas Consumo anual de energia de acordo com a directiva de etiquetagem de energia 2002/31/EC Consumo anual de energia de acordo com a directiva de etiquetagem de energia 2002/31/EC Consumo anual de energia de acordo com a directiva de etiquetagem de energia 2002/31/EC    
  SEER e SCOP de acordo com a EN 14825 SEER e SCOP de acordo com a EN 14825 SEER e SCOP de acordo com a EN 14825    
Eficiência nominal Diretiva de etiqueta da energia Aquecimento       A  
Notas Notes-=-Description       Consumo anual de energia de acordo com a directiva de etiquetagem de energia 2002/31/EC Consumo anual de energia de acordo com a directiva de etiquetagem de energia 2002/31/EC