FCAHG71HVEB / RZQG71L8Y1B |
FCAHG100HVEB / RZQG71L8Y1B |
FCAHG140HVEB / RZQG100L8Y1B |
FCAHG100HVEB / RZQG100L8Y1B |
FCAHG125HVEB / RZQG125L8Y1B |
FCAHG140HVEB / RZQG125L8Y1B |
FCAHG140HVEB / RZQG140L7Y1B |
Capacidade de arrefecimento |
Nom. |
kW |
6.80 |
6.80 |
9.50 |
9.50 |
12.00 |
12.00 |
13.40 |
|
Nom. |
Btu/h |
23,200 |
23,203 |
32,415 |
32,400 |
40,900 |
40,946 |
45,700 |
|
Nom. |
kcal/h |
5,847 |
5,847 |
8,169 |
8,169 |
10,318 |
10,318 |
11,522 |
Capacidade de aquecimento |
Nom. |
kW |
7.50 |
|
|
10.80 |
13.50 |
|
15.50 |
|
Nom. |
Btu/h |
25,600 |
|
|
36,900 |
46,100 |
|
52,900 |
|
Nom. |
kcal/h |
6,449 |
|
|
9,286 |
11,608 |
|
13,328 |
Potência absorvida |
Arrefecimento |
Nom. |
kW |
1.66 |
1.66 |
2.15 |
2.15 |
3.05 |
3.05 |
4.21 |
|
Aquecimento |
Nom. |
kW |
1.56 |
|
|
2.16 |
3.07 |
|
3.76 |
Eficiência nominal |
EER |
|
4.09 |
4.09 |
4.42 |
4.42 |
3.94 |
3.94 |
3.18 |
|
COP |
|
4.80 |
|
|
4.99 |
4.40 |
|
4.12 |
|
Consumo anual de energia |
kWh |
831 |
|
|
1,075 |
1,523 |
|
|
|
Diretiva de etiqueta da energia |
Arrefecimento |
|
A |
|
|
A |
A |
|
|
|
|
Aquecimento |
|
A |
|
|
A |
A |
|
|
Arrefecimento de espaços |
Classe de eficiência energética |
|
A++ |
A++ |
A++ |
A++ |
A++ |
A++ |
|
|
Capacidade |
Pdesign |
kW |
6.80 |
6.80 |
9.50 |
9.50 |
12.00 |
12.00 |
13.40 |
|
SEER |
|
6.91 |
6.91 |
7.00 |
7.00 |
6.61 |
6.61 |
6.75 |
|
ηs,c |
% |
|
|
|
|
|
|
266.88 |
|
Consumo anual de energia |
kWh/a |
345 |
345 |
475 |
475 |
636 |
636 |
1,191 |
|
Condição A (35 °C - 27/19) |
Pdc |
kW |
6.80 |
6.80 |
9.50 |
9.50 |
12.00 |
12.00 |
13.40 |
|
|
EERd |
|
4.09 |
4.09 |
4.42 |
4.42 |
3.94 |
3.94 |
3.18 |
|
|
Potência absorvida |
kW |
1.66 |
1.66 |
2.15 |
2.15 |
3.05 |
3.05 |
4.21 |
|
Condição B (30 °C - 27/19) |
Pdc |
kW |
5.01 |
5.01 |
7.00 |
7.00 |
8.84 |
8.84 |
9.88 |
|
|
EERd |
|
6.23 |
6.23 |
5.87 |
5.87 |
4.74 |
4.74 |
5.07 |
|
|
Potência absorvida |
kW |
0.80 |
0.80 |
1.19 |
1.19 |
1.86 |
1.86 |
1.95 |
|
Condição C (25 °C - 27/19) |
Pdc |
kW |
4.12 |
4.12 |
5.79 |
5.79 |
6.00 |
6.00 |
6.35 |
|
|
EERd |
|
8.49 |
8.49 |
8.70 |
8.70 |
8.33 |
8.33 |
8.36 |
|
|
Potência absorvida |
kW |
0.49 |
0.49 |
0.67 |
0.67 |
0.72 |
0.72 |
0.76 |
|
Condição D (20 °C - 27/19) |
Pdc |
kW |
4.33 |
4.33 |
6.05 |
6.05 |
5.73 |
5.73 |
6.02 |
|
|
EERd |
|
11.52 |
11.52 |
11.27 |
11.27 |
10.86 |
10.86 |
11.13 |
|
|
Potência absorvida |
kW |
0.38 |
0.38 |
0.54 |
0.54 |
0.53 |
0.53 |
0.54 |
Aquecimento ambiente (clima médio) |
Classe de eficiência energética |
|
A+ |
A+ |
A++ |
A++ |
A++ |
A++ |
|
|
Capacidade |
Pdesign |
kW |
7.60 |
7.60 |
11.30 |
11.30 |
12.66 |
12.66 |
11.78 |
|
SCOP/A |
|
4.54 |
4.54 |
4.80 |
4.80 |
4.63 |
4.63 |
4.38 |
|
SCOPnet/A |
|
4.57 |
4.57 |
4.83 |
4.83 |
4.66 |
4.66 |
4.38 |
|
ηs,h |
% |
|
|
|
|
|
|
172.10 |
|
Pdh Heating capacity at -10° |
kW |
6.72 |
6.72 |
9.69 |
9.69 |
11.53 |
11.53 |
0.00 |
|
Consumo anual de energia |
kWh/a |
2,344 |
2,344 |
3,296 |
3,296 |
3,829 |
3,829 |
3,766 |
|
Capacidade de resistência elétrica de apoio nas condições de design |
kW |
0.88 |
0.88 |
1.61 |
1.61 |
1.13 |
1.13 |
11.78 |
|
TOL |
Tol (limite de temperatura de funcionamento) |
°C |
-15 |
-15 |
-15 |
-15 |
-15 |
-15 |
-10 |
|
|
Pdh (capacidade de aquecimento declarada) |
kW |
6.71 |
6.71 |
9.17 |
9.17 |
12.07 |
12.07 |
11.78 |
|
|
COPd (COP declarado) |
|
2.27 |
2.27 |
2.76 |
2.76 |
2.14 |
2.14 |
2.16 |
|
|
Potência absorvida |
kW |
2.96 |
2.96 |
3.32 |
3.32 |
5.64 |
5.64 |
5.45 |
|
TBivalente |
Tbiv (temperatura bivalente) |
°C |
-7 |
-7 |
-7 |
-7 |
-7 |
-7 |
-10 |
|
|
Pdh (capacidade de aquecimento declarada) |
kW |
6.72 |
6.72 |
10.00 |
10.00 |
11.20 |
11.20 |
11.78 |
|
|
COPd (COP declarado) |
|
3.00 |
3.00 |
3.71 |
3.71 |
2.95 |
2.95 |
2.16 |
|
|
Potência absorvida |
kW |
2.24 |
2.24 |
2.70 |
2.70 |
3.80 |
3.80 |
5.45 |
|
Condição A (-7 °C) |
Pdh (capacidade de aquecimento declarada) |
kW |
6.72 |
6.72 |
10.00 |
10.00 |
11.20 |
11.20 |
10.42 |
|
|
COPd (COP declarado) |
|
3.00 |
3.00 |
3.71 |
3.71 |
2.95 |
2.95 |
2.62 |
|
|
Potência absorvida |
kW |
2.24 |
2.24 |
2.70 |
2.70 |
3.80 |
3.80 |
3.96 |
|
Condição B (2 °C) |
Pdh (capacidade de aquecimento declarada) |
kW |
4.70 |
4.70 |
6.45 |
6.45 |
6.82 |
6.82 |
6.34 |
|
|
COPd (COP declarado) |
|
4.19 |
4.19 |
4.25 |
4.25 |
4.26 |
4.26 |
4.45 |
|
|
Potência absorvida |
kW |
1.12 |
1.12 |
1.52 |
1.52 |
1.60 |
1.60 |
1.42 |
|
Condição C (7 °C) |
Pdh (capacidade de aquecimento declarada) |
kW |
2.93 |
2.93 |
4.17 |
4.17 |
4.38 |
4.38 |
4.21 |
|
|
COPd (COP declarado) |
|
7.09 |
7.09 |
6.74 |
6.74 |
7.00 |
7.00 |
5.63 |
|
|
Potência absorvida |
kW |
0.41 |
0.41 |
0.62 |
0.62 |
0.63 |
0.63 |
0.75 |
|
Condição D (12 °C) |
Pdh (capacidade de aquecimento declarada) |
kW |
3.33 |
3.33 |
4.77 |
4.77 |
5.40 |
5.40 |
4.88 |
|
|
COPd (COP declarado) |
|
8.48 |
8.48 |
7.92 |
7.92 |
7.86 |
7.86 |
7.07 |
|
|
Potência absorvida |
kW |
0.39 |
0.39 |
0.60 |
0.60 |
0.69 |
0.69 |
0.69 |
Consumo de energia noutro modo que não o modo ativo |
Crankcase heater mode |
Cooling |
PCK |
kW |
0.000 |
0.000 |
0.000 |
0.000 |
0.000 |
0.000 |
0.000 |
|
|
Heating |
PCK |
kW |
0.000 |
0.000 |
0.000 |
0.000 |
0.000 |
0.000 |
0.012 |
|
Modo desligado |
Arrefecimento |
POFF |
kW |
0.009 |
0.009 |
0.009 |
0.009 |
0.009 |
0.009 |
0.012 |
|
|
Aquecimento |
POFF |
kW |
0.009 |
0.009 |
0.009 |
0.009 |
0.009 |
0.009 |
0.012 |
|
Modo standby |
Arrefecimento |
PSB |
kW |
0.009 |
0.009 |
0.009 |
0.009 |
0.009 |
0.009 |
0.012 |
|
|
Aquecimento |
PSB |
kW |
0.009 |
0.009 |
0.009 |
0.009 |
0.009 |
0.009 |
0.012 |
|
Modo de termostato desligado |
Arrefecimento |
PTO |
kW |
0.007 |
0.007 |
0.009 |
0.009 |
0.009 |
0.009 |
0.000 |
|
|
Aquecimento |
PTO |
kW |
0.007 |
0.007 |
0.009 |
0.009 |
0.009 |
0.009 |
0.012 |
Indication if the heater is equipped with a supplementary heater (pair application) |
|
|
|
|
|
|
Não |
Resistência suplementar (aplicação em par) |
Capacidade de reserva |
Aquecimento |
elbu |
kW |
|
|
|
|
|
|
0.00 |
Arrefecimento |
Cdc (Arrefecimento de deterioração) |
|
0.25 |
0.25 |
0.25 |
0.25 |
0.25 |
0.25 |
0.25 |
Aquecimento |
Cdh (Aquecimento de degradação) |
|
0.25 |
0.25 |
0.25 |
0.25 |
0.25 |
0.25 |
0.25 |
Função de arrefecimento incluída |
Sim |
Sim |
Sim |
Sim |
Sim |
Sim |
Sim |
Função de aquecimento incluída |
Sim |
Sim |
Sim |
Sim |
Sim |
Sim |
Sim |
Clima médio incluído |
Sim |
Sim |
Sim |
Sim |
Sim |
Sim |
Sim |
Estação fria incluída |
Não |
Não |
Não |
Não |
Não |
Não |
Não |
Estação quente incluída |
Não |
Não |
Não |
Não |
Não |
Não |
Não |
Eurovent |
Sound power level outdoor |
Cooling |
Nom. |
dBA |
64 |
|
|
|
|
|
|
|
Nível de potência sonora no interior |
Arrefecimento |
Nom. |
dBA |
53 |
|
|
|
|
|
|
Notas |
(1) - As capacidades de arrefecimento nominais são baseadas em: temperatura interior: 27 °CBs, 19 °CBh, temperatura exterior: 35 °CBs, tubagem de fluido frigorigéneo equivalente: 5 m, desnível: 0 m. |
(1) - Consulte o esquema separado para conhecer os limites de funcionamento |
(1) - Consulte o esquema separado para conhecer os limites de funcionamento |
(1) - As capacidades de arrefecimento nominais são baseadas em: temperatura interior: 27 °CBs, 19 °CBh, temperatura exterior: 35 °CBs, tubagem de fluido frigorigéneo equivalente: 5 m, desnível: 0 m. |
(1) - As capacidades de arrefecimento nominais são baseadas em: temperatura interior: 27 °CBs, 19 °CBh, temperatura exterior: 35 °CBs, tubagem de fluido frigorigéneo equivalente: 5 m, desnível: 0 m. |
(1) - Consulte o esquema separado para conhecer os limites de funcionamento |
(1) - As capacidades de arrefecimento nominais são baseadas em: temperatura interior: 27 °CBs, 19 °CBh, temperatura exterior: 35 °CBs, tubagem de fluido frigorigéneo equivalente: 5 m, desnível: 0 m. |
|
(2) - As capacidades nominais de aquecimento são baseadas em: temperatura interior: 20°CBs, temperatura exterior: 7°CBs, 6°CBh, tubagem de refrigerante equivalente: 5m, diferença de nível: 0m. |
(2) - Consulte o esquema separado para conhecer os dados eléctricos |
(2) - Consulte o esquema separado para conhecer os dados eléctricos |
(2) - As capacidades nominais de aquecimento são baseadas em: temperatura interior: 20°CBs, temperatura exterior: 7°CBs, 6°CBh, tubagem de refrigerante equivalente: 5m, diferença de nível: 0m. |
(2) - As capacidades nominais de aquecimento são baseadas em: temperatura interior: 20°CBs, temperatura exterior: 7°CBs, 6°CBh, tubagem de refrigerante equivalente: 5m, diferença de nível: 0m. |
(2) - Consulte o esquema separado para conhecer os dados eléctricos |
(2) - As capacidades nominais de aquecimento são baseadas em: temperatura interior: 20°CBs, temperatura exterior: 7°CBs, 6°CBh, tubagem de refrigerante equivalente: 5m, diferença de nível: 0m. |
|
(3) - Consulte o esquema separado para conhecer os limites de funcionamento |
|
|
(3) - Consulte o esquema separado para conhecer os limites de funcionamento |
(3) - Consulte o esquema separado para conhecer os limites de funcionamento |
|
(3) - Consulte o esquema separado para conhecer os limites de funcionamento |
|
(4) - Consulte o esquema separado para conhecer os dados eléctricos |
|
|
(4) - Consulte o esquema separado para conhecer os dados eléctricos |
(4) - Consulte o esquema separado para conhecer os dados eléctricos |
|
(4) - Consulte o esquema separado para conhecer os dados eléctricos |