FCQG35FVEB / RXL35K2V1B FCQG50FVEB / RXL50K2V1B
Poff (Modo desligado) W 14.0 15.0
Arrefecimento Psb (Arrefecimento no modo standby) W 14.0 15.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 3.50 5.00
    Consumo anual de energia kWh 217 286
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.65 6.11
    Condição D (20℃ - 27/19) Pdc kW 1.84 2.25
      potência nominal kW 0.17 0.19
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.89 11.74
    Condição C (25℃ - 27/19) potência nominal kW 0.20 0.27
      Pdc kW 1.75 2.37
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.54 8.65
    Condição A (35°C - 27/19) potência nominal kW 0.94 1.36
      Pdc kW 3.50 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.71 3.67
    Condição B (30℃ - 27/19) Pdc kW 2.58 3.67
      potência nominal kW 0.44 0.64
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.81 5.76
  Aquecimento (Clima médio) Consumo anual de energia kWh 1,001 1,463
    Pdesign kW 3.32 4.36
    Tampa resist. apoio necessária em condições de design kW 0.62 0.83
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A++ A+
    TBivalent Pdh (tampa resistência declarada) kW 2.94 3.86
      Consumo kW 1.17 1.67
      Tbiv (temperatura bivalente) °C -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.52 2.31
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 1.47 1.54
      Consumo kW 0.23 0.29
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.29 5.37
    TOL Tol (temperatura-limite funcionamento) °C -25 -25
      Pdh (tampa de resistência declarada) kW 1.50 1.87
      Consumo kW 1.02 1.44
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.47 1.30
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 2.94 3.86
      Consumo kW 1.17 1.67
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.52 2.31
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 1.72 1.79
      Consumo kW 0.23 0.27
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.59 6.71
    Condição B (2℃) Consumo kW 0.35 0.52
      Pdh (tampa de resist. declarada) kW 1.79 2.34
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.09 4.48
Capacidade de arrefecimento Nom. Btu/h 11,590 17,050
  Mín. kW 1.3 1.6
  Nom. kcal/h 2,920 4,300
  Máx. kW 4.0 5.7
  Mín. kcal/h 1,120 1,370
  Mín. Btu/h 4,430 5,450
  Nom. kW 3.40 5.00
  Máx. Btu/h 13,640 19,430
  Máx. kcal/h 3,440 4,900
Pck (Modo aquecedor do cárter) W 0.0 0.0
Eficiência nominal Consumo anual de energia kWh 460 (0.000) 700 (0.000)
  Diretiva de etiqueta da energia Aquecimento A A
  Nominal efficiency-=-Cop 3.70 3.57
Aquecimento Heating-=-Heating cdh degradation heating 0.25 0.25
Capacidade de aquecimento Mín. Btu/h 4,430 5,450
  Nom. Btu/h 14,320 20,460
  Máx. kcal/h 4,470 5,590
  Máx. Btu/h 17,730 22,160
  Nom. kW 4.20 6.00
  Mín. kW 1.3 1.6
  Nom. kcal/h 3,610 5,160
  Mín. kcal/h 1,120 1,370
  Máx. kW 5.2 6.5
Pto (Thermostat off) W 80.0 80.0
Potência absorvida Arrefecimento Mín. kW 0.400 0.530
    Nom. kW 0.920 1.400
    Máx. kW 1.100 1.980
  Aquecimento Máx. kW 1.840 3.530
    Mín. kW 0.230 0.290
    Nom. kW 1.180 1.550
Estação fria incluída Sim Sim
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal