Dados Técnicos para FCQG-F / RXS-L

FCQG35FVEB / RXS35L2V1B FCQG50FVEB / RXS50L2V1B FCQG60FVEB / RXS60L2V1B
Poff (Modo desligado) W 14.0 15.0 15.0
Arrefecimento Psb (Arrefecimento no modo standby) W 14.0 15.0 15.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 3.50 5.00 5.70
    Consumo anual de energia kWh 193 270 321
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.35 6.48 6.22
    Condição D (20℃ - 27/19) Pdc kW 1.53 2.25 2.35
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 12.20 11.74 11.44
    Condição C (25℃ - 27/19) Pdc kW 1.65 2.37 2.69
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.84 8.65 8.05
    Condição A (35°C - 27/19) Pdc kW 3.50 5.00 5.70
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.74 3.67 3.37
    Condição B (30℃ - 27/19) Pdc kW 2.58 3.67 4.20
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.87 5.76 5.34
  Aquecimento (Clima médio) Consumo anual de energia kWh 949 1,426 1,646
    Pdesign kW 3.32 4.36 4.71
    Tampa resist. apoio necessária em condições de design kW 0.72 0.49 0.60
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A++ A++ A+
    TBivalent Pdh (tampa resistência declarada) kW 2.94 3.86 4.17
      Tbiv (temperatura bivalente) °C -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.93 2.49 2.37
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 1.15 1.54 1.64
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.15 5.37 4.92
    TOL Tol (temperatura-limite funcionamento) °C -15 -15 -15
      Pdh (tampa de resistência declarada) kW 2.04 3.89 4.04
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.46 2.05 1.92
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 2.94 3.86 4.17
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.93 2.49 2.37
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 1.29 1.79 1.81
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.97 6.71 6.21
    Condição B (2℃) Pdh (tampa de resist. declarada) kW 1.79 2.34 2.53
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.09 4.48 4.21
Capacidade de arrefecimento Nom. Btu/h 11,590 17,060 19,450
  Mín. kW 1.3 1.7 1.7
  Nom. kcal/h 2,920 4,300 4,900
  Máx. kW 4.0 5.3 5.7
  Mín. kcal/h 1,220 1,460 1,460
  Mín. Btu/h 4,430 5,800 5,800
  Nom. kW 3.4 5.0 5.7
  Máx. Btu/h 13,640 18,100 19,450
  Máx. kcal/h 3,440 4,560 4,900
Pck (Modo aquecedor do cárter) W 0.0 0.0 0.0
Eficiência nominal Annual energy consumption kWh 475 (0.000) 705 (0.000) 820 (0.000)
  Diretiva de etiqueta da energia Aquecimento A A A
  Nominal efficiency-=-Cop 3.58 3.55 3.48
Aquecimento Heating-=-Heating cdh degradation heating 0.25 0.25 0.25
Ligações de tubagens Liquid OD mm 6.35 6.35 6.35
  Gás OD mm 9.5 12.70 12.70
  Esgoto OD mm VP25 (diâmetro externo 32, diâmetro interno 25) VP25 (diâmetro externo 32, diâmetro interno 25) VP25 (diâmetro externo 32, diâmetro interno 25)
  Isolamento de calor Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás
Capacidade de aquecimento Mín. Btu/h 4,430 5,800 5,800
  Nom. Btu/h 1,430 20,472 23,890
  Máx. kcal/h 4,470.0 5,160 6,020
  Máx. Btu/h 17,730 20,500 23,890
  Nom. kW 4.20 6.00 7.0
  Mín. kW 1.3 1.7 1.7
  Nom. kcal/h 3,610 5,160 6,020
  Mín. kcal/h 1,120 1,460 1,460
  Máx. kW 5.2 6.0 7.0
Pto (Thermostat off) W 7.0 7.0 7.0
Potência nominal Arrefecimento Mín. kW 0.400    
    Nom. kW 0.950 1.410 1.640
    Máx. kW 1.100    
  Aquecimento Máx. kW 1.840    
    Mín. kW 0.230    
    Nom. kW 1.200 1.620 1.990
Estação fria incluída Sim Sim Sim
Corrente Corrente de funcionamento nominal - 50Hz Aquecimento A 5.4, 5.1, 4.9 7.6 (1), 7.3 (2), 6.9 (3) 9.3 (1), 8.9 (2), 8.5 (3)
    Arrefecimento A 4.2 (1), 4.0 (2), 3.8 (3) 6.6 (1), 6.3 (2), 6.0 (3) 7.8 (1), 7.4 (2), 7.0 (3)
Notas 220V 220V 220V
  230V 230V 230V
  240V 240V 240V
  EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal