Dados Técnicos para FCQG-F / RXS-L3

FCQG35FVEB / RXS35L3V1B
Poff (Modo desligado) W 14.0
Arrefecimento Psb (Arrefecimento no modo standby) W 14.0
  Cooling-=-Cooling cdc degradation cooling 0.25
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 3.50
    Consumo anual de energia kWh 193
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.35
    Condição D (20℃ - 27/19) Pdc kW 1.53
      potência nominal kW 0.13
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 12.20
    Condição C (25℃ - 27/19) potência nominal kW 0.19
      Pdc kW 1.65
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.84
    Condição A (35°C - 27/19) potência nominal kW 0.94
      Pdc kW 3.50
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.74
    Condição B (30℃ - 27/19) Pdc kW 2.58
      potência nominal kW 0.44
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.87
  Aquecimento (Clima médio) Consumo anual de energia kWh 949
    Pdesign kW 3.32
    Tampa resist. apoio necessária em condições de design kW 0.72
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A++
    TBivalent Pdh (tampa resistência declarada) kW 2.94
      Consumo kW 1.00
      Tbiv (temperatura bivalente) °C -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.93
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 1.15
      Consumo kW 0.19
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.15
    TOL Tol (temperatura-limite funcionamento) °C -15
      Pdh (tampa de resistência declarada) kW 2.04
      Consumo kW 0.83
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.46
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 2.94
      Consumo kW 1.00
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.93
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 1.29
      Consumo kW 0.16
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.97
    Condição B (2℃) Consumo kW 0.35
      Pdh (tampa de resist. declarada) kW 1.79
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.09
Capacidade de arrefecimento Nom. Btu/h 11,590 (2)
  Mín. kW 1.3
  Nom. kcal/h 2,920 (2)
  Máx. kW 4.0
  Mín. kcal/h 1,120
  Mín. Btu/h 4,430
  Nom. kW 3.4 (2)
  Máx. Btu/h 13,640
  Máx. kcal/h 3,440
Pck (Modo aquecedor do cárter) W 0.0
Eficiência nominal Annual energy consumption kWh 455 (0.000)
  Diretiva de etiqueta da energia Aquecimento A
  Nominal efficiency-=-Cop 3.74 (1)
Aquecimento Heating-=-Heating cdh degradation heating 0.25
Ligações de tubagens Liquid OD mm 6.35
  Gás OD mm 9.5
  Esgoto OD mm VP25 (diâmetro externo 32, diâmetro interno 25)
  Isolamento de calor Tubos de líquidos e gás
Capacidade de aquecimento Mín. Btu/h 4,430
  Nom. Btu/h 14,320 (2)
  Máx. kcal/h 4,470
  Máx. Btu/h 17,730
  Nom. kW 4.20 (2)
  Mín. kW 1.3
  Nom. kcal/h 3,610 (2)
  Mín. kcal/h 1,120
  Máx. kW 5.2
Pto (Thermostat off) W 7.0
Potência nominal Arrefecimento Mín. kW 0.400
    Nom. kW 0.909 (2)
    Máx. kW 1.100
  Aquecimento Máx. kW 1.840
    Mín. kW 0.230
    Nom. kW 1.200 (2)
Unidade interior Sim
Corrente Corrente de funcionamento nominal - 50Hz Aquecimento A 5.40 (3), 5.10 (4), 4.90 (5)
    Arrefecimento A 4.02 (3), 3.83 (4), 3.64 (5)
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal
  220V
  230V
  240V