FCQHG71FVEB / RZQG71L7V1B FCQHG71FVEB / RZQG71L7Y1B9 FCQHG100FVEB / RZQG100L7Y1B FCQHG100FVEB / RZQG100L7V1B FCQHG125FVEB / RZQG125L7V1B FCQHG125FVEB / RZQG125L7Y1B
Poff (Modo desligado) W 0.0 0.0 0.0 0.0 0.0 0.0
Arrefecimento Psb (Arrefecimento no modo standby) W 7.0 7.0 9.0 9.0 9.0 9.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25 0.25 0.25 0.25
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 6.80 6.80 9.50 9.50 12.00 12.00
    Consumo anual de energia kWh 389.525 389.525 535.427 535.427 700 700
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.11 6.11 6.21 6.21 6.00 6.00
    Condição D (20℃ - 27/19) Pdc kW 4.33 4.33 6.05 6.05 5.73 5.73
      potência nominal kW 0.45 0.45 0.61 0.61 0.59 0.59
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 9.62 9.53 9.88 9.86 9.68 9.78
    Condição C (25℃ - 27/19) potência nominal kW 0.58 0.59 0.76 0.76 0.81 0.80
      Pdc kW 4.12 4.12 5.79 5.79 6.00 6.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.08 7.02 7.63 7.59 7.44 7.49
    Condição A (35°C - 27/19) potência nominal kW 1.66 1.66 2.15 2.15 3.05 3.05
      Pdc kW 6.80 6.80 9.50 9.50 12.00 12.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.09 4.09 4.42 4.42 3.94 3.94
    Condição B (30℃ - 27/19) Pdc kW 5.01 5.01 7.00 7.00 8.84 8.84
      potência nominal kW 0.82 0.80 1.19 1.18 1.84 1.87
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.12 6.23 5.87 5.92 4.82 4.74
  Aquecimento (Clima médio) Consumo anual de energia kWh 2,545.455 2,545.455 3,680 3,680 5,085 5,085
    Pdesign kW 7.60 7.60 11.30 11.30 14.13 14.13
    Tampa resist. apoio necessária em condições de design kW 0.89 0.88 1.61 1.61 1.77 1.79
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A+ A+ A+ A+ A A
    TBivalent Pdh (tampa resistência declarada) kW 6.72 6.72 10.00 10.00 12.50 12.50
      Consumo kW 2.16 2.24 2.70 2.69 4.47 4.48
      Tbiv (temperatura bivalente) °C -7 -7 -7 -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 3.11 3.00 3.71 3.72 2.80 2.79
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 2.93 2.93 4.17 4.16 4.89 4.89
      Consumo kW 0.47 0.46 0.71 0.70 5.71 5.70
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.26 6.40 5.91 5.92 0.86 0.86
    TOL Tol (temperatura-limite funcionamento) °C -15 -15 -15 -15 -15 -15
      Pdh (tampa de resistência declarada) kW 6.69 6.71 9.17 9.18 12.12 12.07
      Consumo kW 2.88 2.96 3.32 3.34 5.69 5.65
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.32 2.27 2.76 2.75 2.13 2.14
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 6.72 6.72 10.00 10.00 12.50 12.50
      Consumo kW 2.16 2.24 2.70 2.69 4.47 4.48
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 3.11 3.00 3.71 3.72 2.80 2.79
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 3.33 3.33 4.77 4.76 5.40 5.40
      Consumo kW 0.46 0.44 0.69 0.68 0.80 0.80
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.32 7.65 6.93 6.95 6.78 6.76
    Condição B (2℃) Consumo kW 1.24 1.24 1.73 1.73 2.20 2.20
      Pdh (tampa de resist. declarada) kW 4.70 4.70 6.45 6.43 7.61 7.61
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.79 3.78 3.73 3.72 3.45 3.46
Capacidade de arrefecimento Nom. kW 6.8 6.8 9.5 9.5 12.0 12.0
Pck (Modo aquecedor do cárter) W 0.0 0.0 0.0 0.0 0.0 0.0
Eficiência nominal Consumo anual de energia kWh 830 (0.000) 830 (0.000) 1,075 (0.000) 1,075 (0.000) 1,500 (0.000) 1,500 (0.000)
  Diretiva de etiqueta da energia Aquecimento A A A A A A
  Nominal efficiency-=-Cop 4.09 4.09 4.42 4.42 4.00 4.00
Aquecimento Psb (Aquecimento no modo standby) W 14.0 14.0 16.0 16.0 16.0 16.0
  Heating-=-Heating cdh degradation heating 0.25 0.25 0.25 0.25 0.25 0.25
Capacidade de aquecimento Nom. kW 7.5 7.5 10.8 10.8 13.5 13.5
Pto (Thermostat off) W 49.0 49.0 109.0 109.0 120.0 120.0
Estação fria incluída Sim Sim Sim Sim Sim Sim
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal