Specifications Table for FDQ-C / RZQG-L(8)Y1

FDQ125C7VEB / RZQG125L8Y1B
Poff (Modo desligado) W 0
Arrefecimento Psb (Arrefecimento no modo standby) W 9
  Cooling-=-Cooling cdc degradation cooling 0.25
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 12
    Consumo anual de energia kWh 723
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.81
    Condição D (20℃ - 27/19) Pdc kW 5.71
      potência nominal kW 0.64
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 8.96
    Condição C (25℃ - 27/19) potência nominal kW 0.85
      Pdc kW 6.01
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.14
    Condição A (35°C - 27/19) potência nominal kW 3.2
      Pdc kW 12
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.75
    Condição B (30℃ - 27/19) Pdc kW 8.84
      potência nominal kW 2.06
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.3
  Aquecimento (Clima médio) Consumo anual de energia kWh 4,227
    Pdesign kW 12.71
    Tampa resist. apoio necessária em condições de design kW 1.32
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+
    TBivalent Pdh (tampa resistência declarada) kW 11.24
      Consumo kW 4.15
      Tbiv (temperatura bivalente) °C -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.71
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 4.75
      Consumo kW 0.77
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.24
    TOL Tol (temperatura-limite funcionamento) °C -15
      Pdh (tampa de resistência declarada) kW 11.63
      Consumo kW 5.88
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.98
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 11.24
      Consumo kW 4.15
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.71
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 5.4
      Consumo kW 0.75
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.25
    Condição B (2℃) Consumo kW 1.87
      Pdh (tampa de resist. declarada) kW 7.21
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.87
Capacidade de arrefecimento Nom. kW 12.0
Pck (Modo aquecedor do cárter) W 0
Eficiência nominal Consumo anual de energia kWh 1,600 (0.000)
  Diretiva de etiqueta da energia Aquecimento A
  Nominal efficiency-=-Cop 3.75
Aquecimento Psb (Aquecimento no modo standby) W 9
  Heating-=-Heating cdh degradation heating 0.25
Capacidade de aquecimento Nom. kW 13.5
Pto (Thermostat off) W 9
Potência absorvida Arrefecimento Nom. kW 3.20
  Aquecimento Nom. kW 3.53
Unidade interior Sim
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal