FDQ125C7VEB / RZQSG125L8V1B
Poff (Modo desligado) W 0.0
Arrefecimento Psb (Arrefecimento no modo standby) W 7.0
  Cooling-=-Cooling cdc degradation cooling 0.25
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 12.00
    Consumo anual de energia kWh 807.692
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.20
    Condição D (20℃ - 27/19) Pdc kW 4.04
      potência nominal kW 0.47
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 8.52
    Condição C (25℃ - 27/19) potência nominal kW 0.86
      Pdc kW 5.69
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 6.59
    Condição A (35°C - 27/19) potência nominal kW 3.88
      Pdc kW 12.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.09
    Condição B (30℃ - 27/19) Pdc kW 8.84
      potência nominal kW 2.59
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 3.41
  Aquecimento (Clima médio) Consumo anual de energia kWh 2,728.205
    Pdesign kW 7.60
    Tampa resist. apoio necessária em condições de design kW 0.58
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A
    TBivalent Pdh (tampa resistência declarada) kW 6.72
      Consumo kW 2.33
      Tbiv (temperatura bivalente) °C -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.89
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 3.02
      Consumo kW 0.59
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.12
    TOL Tol (temperatura-limite funcionamento) °C -15
      Pdh (tampa de resistência declarada) kW 7.51
      Consumo kW 3.39
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.21
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 6.72
      Consumo kW 2.33
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.89
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 3.42
      Consumo kW 0.57
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.00
    Condição B (2℃) Consumo kW 1.26
      Pdh (tampa de resist. declarada) kW 4.85
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.86
Capacidade de arrefecimento Nom. kW 12.0
Pck (Modo aquecedor do cárter) W 0.0
Eficiência nominal Consumo anual de energia kWh 1,870 (0.000)
  Diretiva de etiqueta da energia Aquecimento A
  Nominal efficiency-=-Cop 3.21
Aquecimento Psb (Aquecimento no modo standby) W 7.0
  Heating-=-Heating cdh degradation heating 0.25
Capacidade de aquecimento Nom. kW 13.5
Pto (Thermostat off) W 7.0
Potência absorvida Arrefecimento Nom. kW 3.74
  Aquecimento Nom. kW 3.85
Estação fria incluída Sim
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal