FDXS60F2VEB / RXS60F4V1B
Poff (Modo desligado) W 20.0
Arrefecimento Psb (Arrefecimento no modo standby) W 20.0
  Cooling-=-Cooling cdc degradation cooling 0.25
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 6.00
    Consumo anual de energia kWh 382
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.50
    Condição D (20℃ - 27/19) Pdc kW 2.11
      potência nominal kW 0.19
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.85
    Condição C (25℃ - 27/19) potência nominal kW 0.32
      Pdc kW 2.37
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.41
    Condição A (35°C - 27/19) potência nominal kW 1.76
      Pdc kW 6.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.41
    Condição B (30℃ - 27/19) Pdc kW 3.67
      potência nominal kW 0.75
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.90
  Aquecimento (Clima médio) Consumo anual de energia kWh 1,596
    Pdesign kW 4.00
    Tampa resist. apoio necessária em condições de design kW 0.84
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A
    TBivalent Pdh (tampa resistência declarada) kW 3.54
      Consumo kW 1.62
      Tbiv (temperatura bivalente) °C -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.19
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 1.43
      Consumo kW 0.34
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.24
    TOL Tol (temperatura-limite funcionamento) °C -15
      Pdh (tampa de resistência declarada) kW 2.55
      Consumo kW 1.47
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.73
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 3.54
      Consumo kW 1.62
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.19
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 1.67
      Consumo kW 0.30
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 5.48
    Condição B (2℃) Consumo kW 0.52
      Pdh (tampa de resist. declarada) kW 1.92
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.69
Capacidade de arrefecimento Nom. Btu/h 20,500 (2)
  Mín. kW 1.7
  Nom. kcal/h 5,160 (2)
  Máx. kW 6.5
  Mín. kcal/h 1,460
  Mín. Btu/h 5,800
  Nom. kW 6.0 (2)
  Máx. Btu/h 22,200
  Máx. kcal/h 5,590
Pck (Modo aquecedor do cárter) W 0.0
Eficiência nominal Consumo anual de energia kWh 1,030 (0.000)
  Diretiva de etiqueta da energia Aquecimento C
  Nominal efficiency-=-Cop 2.91 (1)
Aquecimento Heating-=-Heating cdh degradation heating 0.25
Ligações de tubagens Liquid OD mm 6.35
  Gás OD mm 12.7
  Esgoto OD mm VP20 (diâmetro externo 26, diâmetro interno 20)
  Isolamento de calor Tubos de líquidos e gás
Capacidade de aquecimento Mín. Btu/h 5,800
  Nom. Btu/h 23,900 (3)
  Máx. kcal/h 6,880
  Máx. Btu/h 27,300
  Nom. kW 7.0 (3)
  Mín. kW 1.7
  Nom. kcal/h 6,020 (3)
  Mín. kcal/h 1,460
  Máx. kW 8.0
Pto (Thermostat off) W 80.0
Potência absorvida Arrefecimento Nom. kW 2.060
  Aquecimento Nom. kW 2.180
Estação fria incluída Sim
Current Corrente de funcionamento nominal - 50Hz Aquecimento A 10.0
    Arrefecimento A 9.2
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m
  Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal