FDXS25F2VEB / RXS25L2V1B FDXS35F2VEB / RXS35L2V1B FDXS60F2VEB / RXS60L2V1B
Poff (Modo desligado) W 14.0 14.0 15.0
Arrefecimento Psb (Arrefecimento no modo standby) W 14.0 14.0 15.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 2.40 3.40 6.00
    Consumo anual de energia kWh 149 228 381
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.63 5.21 5.51
    Condição D (20℃ - 27/19) Pdc kW 1.33 1.46 2.26
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.66 9.80 10.38
    Condição C (25℃ - 27/19) Pdc kW 1.27 1.61 2.85
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.43 7.02 6.90
    Condição A (35°C - 27/19) Pdc kW 2.40 3.40 6.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.74 2.96 2.91
    Condição B (30℃ - 27/19) Pdc kW 1.76 2.50 4.43
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.89 4.68 4.57
  Aquecimento (Clima médio) Consumo anual de energia kWh 858 1,047 1,693
    Pdesign kW 2.60 2.90 4.60
    Tampa resist. apoio necessária em condições de design kW 0.44 0.48 0.66
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A+ A A
    TBivalent Pdh (tampa resistência declarada) kW 2.30 2.57 4.07
      Tbiv (temperatura bivalente) °C -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.51 2.33 2.16
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 1.00 1.02 1.62
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.50 4.80 4.92
    TOL Tol (temperatura-limite funcionamento) °C -15 -15 -15
      Pdh (tampa de resistência declarada) kW 1.93 2.15 3.72
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.13 1.92 1.83
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 2.30 2.57 4.07
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.51 2.33 2.16
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 1.17 1.19 1.92
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.95 6.26 6.15
    Condição B (2℃) Pdh (tampa de resist. declarada) kW 1.40 1.57 2.48
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.39 4.02 3.95
Capacidade de arrefecimento Nom. Btu/h 8,150 11,500 20,500
  Mín. kW 1.3 1.4 1.7
  Nom. kcal/h 2,060 2,920 5,160
  Máx. kW 3.0 3.8 6.5
  Mín. kcal/h 1,110 1,200 1,460
  Mín. Btu/h 4,400 4,800 5,800
  Nom. kW 2.4 3.4 6.0
  Máx. Btu/h 10,200 13,000 22,200
  Máx. kcal/h 2,580 3,260 5,590
Pck (Modo aquecedor do cárter) W 0.0 0.0 0.0
Eficiência nominal Consumo anual de energia kWh 325 (0.000) 530 (0.000) 1,030 (0.000)
  Diretiva de etiqueta da energia Aquecimento A A C
  Nominal efficiency-=-Cop 3.69 3.21 2.91
Aquecimento Heating-=-Heating cdh degradation heating 0.25 0.25 0.25
Ligações de tubagens Liquid OD mm 6.35 6.35 6.35
  Gás OD mm 9.5 9.5 12.7
  Esgoto OD mm VP20 (diâmetro externo 26, diâmetro interno 20) VP20 (diâmetro externo 26, diâmetro interno 20) VP20 (diâmetro externo 26, diâmetro interno 20)
  Isolamento de calor Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás
Capacidade de aquecimento Mín. Btu/h 4,400 4,800 5,800
  Nom. Btu/h 10,900 13,600 23,900
  Máx. kcal/h 3,870 4,300 6,880
  Máx. Btu/h 15,350 17,100 27,300
  Nom. kW 3.2 4.0 7.0
  Mín. kW 1.3 1.4 1.7
  Nom. kcal/h 2,750 3,440 6,020
  Mín. kcal/h 1,110 1,200 1,460
  Máx. kW 4.5 5.0 8.0
Pto (Thermostat off) W 7.0 7.0 9.0
Potência absorvida Arrefecimento Nom. kW 0.650 1.060 2.060
  Aquecimento Nom. kW 0.800 1.150 2.180
Estação fria incluída Sim Sim Sim
Current Corrente de funcionamento nominal - 50Hz Aquecimento A 4.2 (2) 5.4 (2) 10.0 (2)
    Arrefecimento A 3.9 (2) 4.9 (2) 9.2 (2)
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  230V 230V 230V
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal