Specifications Table for FHQ-C / RZQG-L(8)Y1

FHQ100CAVEB / RZQG71L8Y1B FHQ71CAVEB / RZQG71L8Y1B FHQ140CAVEB / RZQG100L8Y1B FHQ100CAVEB / RZQG100L8Y1B FHQ140CAVEB / RZQG125L8Y1B FHQ125CAVEB / RZQG125L8Y1B FHQ71CAVEB / FHQ71CAVEB / RZQG125L8Y1B FHQ140CAVEB / RZQG140L7Y1B
Poff (Modo desligado) W 0.0 0 0.0 0 0.0 0 0.0  
Arrefecimento Psb (Arrefecimento no modo standby) W 7.0 7 9.0 9 9.0 9 13.0  
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25 0.25 0.25 0.25 0.25  
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 6.80 6.8 9.50 9.5 12.00 12 12.00  
    Consumo anual de energia kWh 343 343 545 545 699 699 824  
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy label 6.95 6.95 6.11 6.11 6.01 6.01 5.10  
    Condição D (20℃ - 27/19) Pdc kW 4.17 4.17 5.87 5.87 5.64 5.64 5.85  
      potência nominal kW 0.34 0.34 0.58 0.58 0.59 0.59 0.78  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 12.58 12.58 10.14 10.14 9.69 9.69 7.55  
    Condição C (25℃ - 27/19) potência nominal kW 0.43 0.43 0.73 0.73 0.80 0.8 1.04  
      Pdc kW 4.01 4.01 5.66 5.66 5.92 5.92 6.10  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 9.47 9.47 7.86 7.86 7.45 7.45 5.92  
    Condição A (35°C - 27/19) potência nominal kW 1.79 1.79 2.31 2.31 3.41 3.41 3.33  
      Pdc kW 6.80 6.8 9.50 9.5 12.00 12 12.00  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 3.82 3.82 4.13 4.13 3.52 3.52 3.61  
    Condição B (30℃ - 27/19) Pdc kW 5.16 5.16 7.16 7.16 8.84 8.84 8.84  
      potência nominal kW 1.04 1.04 1.60 1.6 2.00 2 1.84  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.00 5 4.50 4.5 4.44 4.44 4.82  
  Aquecimento (Clima médio) Consumo anual de energia kWh 2,463 2,463 3,432 3,432 4,677 4,677 4,683  
    Pdesign kW 7.60 7.6 11.30 11.3 14.13 14.13 12.71  
    Tampa resist. apoio necessária em condições de design kW 0.86 0.86 1.59 1.59 1.62 1.62 1.29  
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop A+ A+ A++ A++ A+ A+ A  
    TBivalent Pdh (tampa resistência declarada) kW 6.72 6.72 10.00 10 12.50 12.5 11.24  
      Consumo kW 2.28 2.28 2.78 2.78 4.97 4.97 3.68  
      Tbiv (temperatura bivalente) °C -7 -7 -7 -7 -7 -7 -7  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.95 2.95 3.61 3.61 2.52 2.52 3.06  
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 2.95 2.95 4.21 4.21 4.89 4.89 4.74  
      Consumo kW 0.45 0.45 0.65 0.65 0.75 0.75 0.89  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.67 6.67 6.54 6.54 6.57 6.57 5.33  
    TOL Tol (temperatura-limite funcionamento) °C -15 -15 -15 -15 -15 -15 -15  
      Pdh (tampa de resistência declarada) kW 6.76 6.76 9.22 9.22 12.52 12.52 11.72  
      Consumo kW 3.21 3.21 3.50 3.5 6.05 6.05 5.41  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.11 2.11 2.64 2.64 2.07 2.07 2.17  
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 6.72 6.72 10.00 10 12.50 12.5 11.24  
      Consumo kW 2.28 2.28 2.78 2.78 4.97 4.97 3.68  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.95 2.95 3.61 3.61 2.52 2.52 3.06  
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 3.36 3.36 4.81 4.81 5.37 5.37 5.39  
      Consumo kW 0.44 0.44 0.64 0.64 0.74 0.74 0.87  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.70 7.7 7.58 7.58 7.35 7.35 6.22  
    Condição B (2℃) Consumo kW 1.19 1.19 1.62 1.62 1.95 1.95 2.17  
      Pdh (tampa de resist. declarada) kW 4.74 4.74 6.54 6.54 7.61 7.61 7.20  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.99 3.99 4.04 4.04 3.92 3.92 3.33  
Capacidade de arrefecimento Nom. kW   6.8   9.5   12.0   13.4
Pck (Modo aquecedor do cárter) W 0.0 0 0.0 0 0.0 0 0.0  
Eficiência nominal Consumo anual de energia kWh   890 (0.000)   1,245 (0.000)   1,790 (0.000)    
Aquecimento Psb (Aquecimento no modo standby) W 7.0 7 9.0 9 9.0 9 16.0  
  Heating-=-Heating cdh degradation heating 0.25 0.25 0.25 0.25 0.25 0.25 0.25  
Capacidade de aquecimento Nom. kW   7.5   10.8   13.5   15.5
Pto (Thermostat off) W 7.0 7 9.0 9 9.0 9 142.0  
Potência absorvida Arrefecimento Nom. kW   1.78   2.49   3.58   4.05
  Aquecimento Nom. kW   1.82   2.60   3.48   4.27
Unidade interior sim Sim sim Sim Sim Sim Sim RZQG140LY1
Eficiência nominal Diretiva de etiqueta da energia Aquecimento   A   A   A    
  Nominal efficiency-=-Cop   3.82   3.81   3.35   3.31
Notas   EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE   EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE   EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE   EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
    Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal   Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal   Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal   Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal