FHQ71CAVEB / RZQG71L7V1B |
FHQ71CAVEB / RZQG71L7Y1B9 |
FHQ100CAVEB / RZQG100L7Y1B |
FHQ100CAVEB / RZQG100L7V1B |
FHQ125CAVEB / RZQG125L7V1B |
FHQ125CAVEB / RZQG125L7Y1B |
Poff (Modo desligado) |
W |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Arrefecimento |
Psb (Arrefecimento no modo standby) |
W |
7.0 |
7.0 |
9.0 |
9.0 |
9.0 |
9.0 |
|
Cooling-=-Cooling cdc degradation cooling |
0.25 |
0.25 |
0.25 |
0.25 |
0.25 |
0.25 |
Eficiência sazonal (de acordo com EN14825) |
Arrefecimento |
Pdesign |
kW |
6.80 |
6.80 |
9.50 |
9.50 |
12.00 |
12.00 |
|
|
Consumo anual de energia |
kWh |
407 |
406.838 |
584.358 |
584 |
806.142 |
806.142 |
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class |
5.85 |
5.85 |
5.69 |
5.69 |
5.21 |
5.21 |
|
|
Condição D (20℃ - 27/19) |
Pdc |
kW |
4.17 |
4.17 |
5.87 |
5.87 |
5.64 |
5.64 |
|
|
|
potência nominal |
kW |
0.39 |
0.39 |
0.60 |
0.61 |
0.71 |
0.70 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd |
10.56 |
10.57 |
9.71 |
9.70 |
7.93 |
8.00 |
|
|
Condição C (25℃ - 27/19) |
potência nominal |
kW |
0.51 |
0.50 |
0.75 |
0.75 |
0.97 |
0.96 |
|
|
|
Pdc |
kW |
4.01 |
4.01 |
5.66 |
5.66 |
5.92 |
5.92 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd |
7.93 |
7.95 |
7.53 |
7.54 |
6.12 |
6.16 |
|
|
Condição A (35°C - 27/19) |
potência nominal |
kW |
1.78 |
1.78 |
2.30 |
2.30 |
3.41 |
3.41 |
|
|
|
Pdc |
kW |
6.80 |
6.80 |
9.50 |
9.50 |
12.00 |
12.00 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd |
3.82 |
3.82 |
4.13 |
4.13 |
3.52 |
3.52 |
|
|
Condição B (30℃ - 27/19) |
Pdc |
kW |
5.16 |
5.16 |
7.16 |
7.16 |
8.84 |
8.84 |
|
|
|
potência nominal |
kW |
1.22 |
1.23 |
1.66 |
1.66 |
1.96 |
1.99 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd |
4.22 |
4.21 |
4.30 |
4.30 |
4.51 |
4.44 |
|
Aquecimento (Clima médio) |
Consumo anual de energia |
kWh |
2,692 |
2,692 |
3,681 |
3,681 |
4,676.596 |
4,676.596 |
|
|
Pdesign |
kW |
7.60 |
7.60 |
11.30 |
11.30 |
14.13 |
14.13 |
|
|
Tampa resist. apoio necessária em condições de design |
kW |
0.86 |
0.86 |
1.59 |
1.59 |
1.62 |
1.62 |
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a |
A |
A |
A+ |
A+ |
A+ |
A+ |
|
|
TBivalent |
Pdh (tampa resistência declarada) |
kW |
6.72 |
6.72 |
10.00 |
10.00 |
12.50 |
12.50 |
|
|
|
Consumo |
kW |
2.26 |
2.28 |
2.77 |
2.76 |
4.96 |
4.96 |
|
|
|
Tbiv (temperatura bivalente) |
°C |
-7 |
-7 |
-7 |
-7 |
-7 |
-7 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop |
2.97 |
2.95 |
3.61 |
3.62 |
2.52 |
2.52 |
|
|
Condição C (7℃) |
Pdh (tampa de resist. declarada) |
kW |
2.96 |
2.95 |
4.21 |
4.20 |
4.89 |
4.89 |
|
|
|
Consumo |
kW |
0.50 |
0.49 |
0.70 |
0.70 |
0.74 |
0.74 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop |
5.93 |
5.98 |
6.03 |
6.04 |
6.60 |
6.61 |
|
|
TOL |
Tol (temperatura-limite funcionamento) |
°C |
-15 |
-15 |
-15 |
-15 |
-15 |
-15 |
|
|
|
Pdh (tampa de resistência declarada) |
kW |
6.76 |
6.76 |
9.22 |
9.23 |
12.52 |
12.52 |
|
|
|
Consumo |
kW |
3.16 |
3.20 |
3.50 |
3.51 |
6.09 |
6.06 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop |
2.14 |
2.11 |
2.64 |
2.63 |
2.06 |
2.07 |
|
|
Condição A (-7°C) |
Pdh (tampa de resist. declarada) |
kW |
6.72 |
6.72 |
10.00 |
10.00 |
12.50 |
12.50 |
|
|
|
Consumo |
kW |
2.26 |
2.28 |
2.77 |
2.76 |
4.96 |
4.96 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop |
2.97 |
2.95 |
3.61 |
3.62 |
2.52 |
2.52 |
|
|
Condição D (12℃) |
Pdh (tampa de resist. declarada) |
kW |
3.37 |
3.36 |
4.81 |
4.80 |
5.36 |
5.37 |
|
|
|
Consumo |
kW |
0.49 |
0.49 |
0.69 |
0.69 |
0.69 |
0.73 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop |
6.85 |
6.91 |
6.98 |
7.00 |
7.76 |
7.39 |
|
|
Condição B (2℃) |
Consumo |
kW |
1.33 |
1.32 |
1.76 |
1.76 |
1.94 |
1.93 |
|
|
|
Pdh (tampa de resist. declarada) |
kW |
4.76 |
4.74 |
6.54 |
6.52 |
7.61 |
7.61 |
|
|
|
Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop |
3.59 |
3.58 |
3.73 |
3.71 |
3.92 |
3.95 |
Capacidade de arrefecimento |
Nom. |
kW |
6.8 |
6.8 |
9.5 |
9.5 |
12.0 |
12.0 |
Pck (Modo aquecedor do cárter) |
W |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
Eficiência nominal |
Consumo anual de energia |
kWh |
890 (0.000) |
890 (0.000) |
1,245 (0.000) |
1,245 (0.000) |
1,790 (0.000) |
1,790 (0.000) |
|
Diretiva de etiqueta da energia |
Aquecimento |
A |
A |
A |
A |
A |
A |
|
Nominal efficiency-=-Cop |
3.82 |
3.82 |
4.13 |
4.13 |
3.52 |
3.52 |
Aquecimento |
Psb (Aquecimento no modo standby) |
W |
14.0 |
14.0 |
16.0 |
16.0 |
16.0 |
16.0 |
|
Heating-=-Heating cdh degradation heating |
0.25 |
0.25 |
0.25 |
0.25 |
0.25 |
0.25 |
Capacidade de aquecimento |
Nom. |
kW |
7.5 |
7.5 |
10.8 |
10.8 |
13.5 |
13.5 |
Pto (Thermostat off) |
W |
56.0 |
56.0 |
98.0 |
98.0 |
117.0 |
117.0 |
Estação fria incluída |
Sim |
Sim |
Sim |
Sim |
Sim |
Sim |
Notas |
EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE |
EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE |
EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE |
EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE |
EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE |
EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE |
|
Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal |
Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal |
Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal |
Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal |
Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal |
Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal |