FLXS35BAVMB9 / RXS35L2V1B
Poff (Modo desligado) W 14.0
Arrefecimento Psb (Arrefecimento no modo standby) W 14.0
  Cooling-=-Cooling cdc degradation cooling 0.25
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 3.50
    Consumo anual de energia kWh 252
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 4.87
    Condição D (20℃ - 27/19) Pdc kW 1.42
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 9.91
    Condição C (25℃ - 27/19) Pdc kW 1.66
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 6.90
    Condição A (35°C - 27/19) Pdc kW 3.50
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 2.88
    Condição B (30℃ - 27/19) Pdc kW 2.58
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 4.59
  Aquecimento (Clima médio) Consumo anual de energia kWh 1,068
    Pdesign kW 2.90
    Tampa resist. apoio necessária em condições de design kW 0.45
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A
    TBivalent Pdh (tampa resistência declarada) kW 2.57
      Tbiv (temperatura bivalente) °C -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.30
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 1.05
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 4.81
    TOL Tol (temperatura-limite funcionamento) °C -15
      Pdh (tampa de resistência declarada) kW 2.25
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.90
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 2.57
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.30
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 1.23
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.22
    Condição B (2℃) Pdh (tampa de resist. declarada) kW 1.56
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 3.98
Capacidade de arrefecimento Nom. Btu/h 11,900
  Mín. kW 1.2
  Nom. kcal/h 3,010
  Máx. kW 3.8
  Mín. kcal/h 1,030
  Mín. Btu/h 4,100
  Nom. kW 3.5
  Máx. Btu/h 13,000
  Máx. kcal/h 3,270
Pck (Modo aquecedor do cárter) W 0.0
Eficiência nominal Consumo anual de energia kWh 565 (0.000)
  Diretiva de etiqueta da energia Aquecimento B
  Nominal efficiency-=-Cop 3.10
Aquecimento Heating-=-Heating cdh degradation heating 0.25
Ligações de tubagens Líquido OD mm 6.35
  Gás OD mm 9.5
  Esgoto OD mm 18.0
  Isolamento de calor Tubos de líquidos e gás
Capacidade de aquecimento Mín. Btu/h 4,100
  Nom. Btu/h 13,600
  Máx. kcal/h 4,300
  Máx. Btu/h 17,100
  Nom. kW 4.0
  Mín. kW 1.4
  Nom. kcal/h 3,440
  Mín. kcal/h 1,030
  Máx. kW 5.0
Pto (Thermostat off) W 75.0
Potência nominal Arrefecimento Mín. kW 0.300
    Nom. kW 1.130
    Máx. kW 1.260
  Aquecimento Máx. kW 1.850
    Mín. kW 0.290
    Nom. kW 1.120
Estação fria incluída Sim
Corrente Corrente de funcionamento nominal - 50Hz Aquecimento A 5.6 (2), 5.3 (3), 5.1 (4)
    Arrefecimento A 5.3 (2), 5.1 (3), 4.9 (4)
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  220V
  230V
  240V
  Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m
  Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal