Dados Técnicos para FTX-J3 / RX-K

FTX20J3V1B / RX20K5V1B FTX20J3V1B / RX20K2V1B FTX25J3V1B / RX25K5V1B FTX25J3V1B / RX25K2V1B FTX35J3V1B / RX35K5V1B FTX35J3V1B / RX35K2V1B
Poff (Modo desligado) W 1.0 1.0 1.0 1.0 1.0 1.0
Arrefecimento Psb (Arrefecimento no modo standby) W 1.0 1.0 1.0 1.0 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25 0.25 0.25 0.25
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 2.00 2.00 2.50 2.50 3.30 3.30
    Consumo anual de energia kWh 115 115 143 142 188 188
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.11 6.11 6.15 6.15 6.15 6.15
    Condição D (20℃ - 27/19) Pdc kW 1.15 1.15 1.15 1.15 1.20 1.20
      potência nominal kW 0.13 0.12 0.13 0.13 0.13 0.12
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 9.46 9.46 9.20 9.20 9.91 9.91
    Condição C (25℃ - 27/19) potência nominal kW 0.17 0.16 0.16 0.16 0.23 0.23
      Pdc kW 1.22 1.22 1.22 1.22 1.60 1.60
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.55 7.55 7.80 7.80 6.98 6.98
    Condição A (35°C - 27/19) potência nominal kW 0.49 0.49 0.71 0.70 1.03 1.03
      Pdc kW 2.00 2.00 2.50 2.50 3.30 3.30
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.09 4.09 3.55 3.55 3.21 3.21
    Condição B (30℃ - 27/19) Pdc kW 1.56 1.56 1.84 1.84 2.43 2.43
      potência nominal kW 0.27 0.27 0.35 0.35 0.44 0.44
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 5.83 5.83 5.27 5.27 5.55 5.55
  Aquecimento (Clima médio) Consumo anual de energia kWh 710 711 808 809 947 947
    Pdesign kW 2.20 2.20 2.40 2.40 2.80 2.80
    Tampa resist. apoio necessária em condições de design kW 0.38 0.39 0.42 0.43 0.50 0.50
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scopnet a A+ A+ A+ A+ A+ A+
    TBivalent Pdh (tampa resistência declarada) kW 1.95 1.95 2.13 2.13 2.48 2.48
      Consumo kW 0.71 0.71 0.86 0.85 1.11 1.11
      Tbiv (temperatura bivalente) °C -7 -7 -7 -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.76 2.76 2.50 2.50 2.24 2.24
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 0.90 0.90 0.89 0.89 1.00 1.00
      Consumo kW 0.16 0.16 0.16 0.16 0.18 0.18
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.70 5.70 5.61 5.61 5.60 5.60
    TOL Tol (temperatura-limite funcionamento) °C -15 -15 -15 -15 -15 -15
      Pdh (tampa de resistência declarada) kW 1.59 1.59 1.72 1.72 1.99 1.99
      Consumo kW 0.65 0.65 0.75 0.74 0.94 0.94
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.46 2.46 2.31 2.31 2.12 2.12
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 1.95 1.95 2.13 2.13 2.48 2.48
      Consumo kW 0.71 0.71 0.86 0.85 1.11 1.11
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.76 2.76 2.50 2.50 2.24 2.24
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 1.02 1.02 1.02 1.02 1.10 1.10
      Consumo kW 0.15 0.15 0.16 0.15 0.17 0.16
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.85 6.85 6.74 6.74 6.86 6.86
    Condição B (2℃) Consumo kW 0.27 0.27 0.31 0.31 0.36 0.35
      Pdh (tampa de resist. declarada) kW 1.18 1.18 1.29 1.29 1.51 1.51
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.45 4.45 4.19 4.19 4.31 4.31
Capacidade de arrefecimento Nom. Btu/h 6,800 (2) 6,800 (2) 8,500 (2) 8,500 (2) 11,300 (2) 11,300 (2)
  Mín. kW 1.3 1.3 1.3 1.3 1.3 1.3
  Nom. kcal/h 1,720 (2) 1,720 (2) 2,150 (2) 2,150 (2) 2,840 (2) 2,840 (2)
  Máx. kW 2.6 2.6 3.0 3.0 3.8 3.8
  Mín. kcal/h 1,120 1,120 1,120 1,120 1,120 1,120
  Mín. Btu/h 4,400 4,400 4,400 4,400 4,400 4,400
  Nom. kW 2.0 (2) 2.0 (2) 2.5 (2) 2.5 (2) 3.3 (2) 3.3 (2)
  Máx. Btu/h 8,900 8,900 10,200 10,200 13,000 13,000
  Máx. kcal/h 2,240 2,240 2,580 2,580 3,270 3,270
Pck (Modo aquecedor do cárter) W 0.0 0.0 0.0 0.0 0.0 0.0
Eficiência nominal Annual energy consumption kWh 244 (0.000) 244 (0.000) 352 (0.000) 352 (0.000) 514 (0.000) 514 (0.000)
  Diretiva de etiqueta da energia Aquecimento A A A A A A
  Nominal efficiency-=-Cop 4.09 (1) 4.09 (1) 3.55 (1) 3.55 (1) 3.21 (1) 3.21 (1)
Aquecimento Psb (Aquecimento no modo standby) W 1.0   1.0   1.0  
  Heating-=-Heating cdh degradation heating 0.25 0.25 0.25 0.25 0.25 0.25
Ligações de tubagens Liquid OD mm 6.35 6.35 6.35 6.35 6.35 6.35
  Gás OD mm 9.5 9.5 9.5 9.5 9.5 9.5
  Esgoto OD mm 18 18 18 18 18 18
  Isolamento de calor Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás
Capacidade de aquecimento Mín. Btu/h 4,400 4,400 4,400 4,400 4,400 4,400
  Nom. Btu/h 8,500 (2) 8,500 (2) 9,600 (2) 9,600 (2) 11,900 (2) 11,900 (2)
  Máx. kcal/h 3,010 3,010 3,440 3,440 4,130 4,130
  Máx. Btu/h 11,900 11,900 13,600 13,600 16,400 16,400
  Nom. kW 2.5 (2) 2.5 (2) 2.8 (2) 2.8 (2) 3.5 (2) 3.5 (2)
  Mín. kW 1.3 1.3 1.3 1.3 1.3 1.3
  Nom. kcal/h 2,150 (2) 2,150 (2) 2,410 (2) 2,410 (2) 3,010 (2) 3,010 (2)
  Mín. kcal/h 1,120 1,120 1,120.0 1,120.0 1,120 1,120
  Máx. kW 3.5 3.5 4.0 4.0 4.8 4.8
Pto (Thermostat off) W 30.0 30.0 30.0 30.0 30.0 30.0
Potência nominal Arrefecimento Mín. kW 0.310 0.310 0.310 0.310 0.290 0.290
    Nom. kW 0.490 (2) 0.490 (2) 0.700 (2) 0.700 (2) 1.030 (2) 1.030 (2)
    Máx. kW 0.720 0.720 1.050 1.050 1.300 1.300
  Aquecimento Máx. kW 0.950 0.950 1.110 1.110 1.290 1.290
    Mín. kW 0.250 0.250 0.250 0.250 0.290 0.290
    Nom. kW 0.590 (2) 0.590 (2) 0.690 (2) 0.690 (2) 0.930 (2) 0.930 (2)
Unidade interior Sim Sim Sim Sim Sim Sim
Corrente Corrente de funcionamento nominal - 50Hz Aquecimento A 3.0 3.0 3.2 3.2 4.7 4.7
    Arrefecimento A 2.4 2.4 3.6 3.6 5.5 5.5
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal