FTXM20M2V1B / RXM20M3V1B9 FTXM25M2V1B / RXM25M3V1B9 FTXM35M2V1B / RXM35M3V1B9 FTXM42M2V1B / RXM42M3V1B9 FTXM50M2V1B / RXM50M3V1B9 FTXM60M2V1B / RXM60M3V1B9
Unidade interior FTXM20M2V1B FTXM25M2V1B FTXM35M2V1B FTXM42M2V1B FTXM50M2V1B FTXM60M2V1B
Unidade exterior RXM20M3V1B9 RXM25M3V1B9 RXM35M3V1B9 RXM42M3V1B9 RXM50M3V1B9 RXM60M3V1B9
Capacidade de arrefecimento Mín. kW 1.3 1.3 1.4 1.70 1.70 1.90
  Mín. Btu/h 4,400.0 4,400.0 4,800.0 5,800 5,800 6,500
  Mín. kcal/h 1,120.0 1,120.0 1,200.0 1,460 1,460 1,700
  Nom. kW 2.0 2.5 3.4 4.20 5.00 6.00
  Nom. Btu/h 6,800.0 8,500.0 11,600.0 14,300 17,100 20,500
  Nom. kcal/h 1,720.0 2,150.0 2,920.0 3,610 4,300 5,160
  Máx. kW 2.6 3.2 4.0 5.00 5.30 6.70
  Máx. Btu/h 8,900.0 11,000.0 13,600.0 17,100 18,100 22,900
  Máx. kcal/h 2,240.0 2,750.0 3,440.0 4,300 4,560 5,800
Capacidade de aquecimento Mín. kW 1.30 1.30 1.40 1.70 1.70 1.70
  Mín. Btu/h 4,400.0 4,400.0 4,800.0 5,800 5,800 5,800
  Mín. kcal/h 1,120.0 1,120.0 1,200.0 1,460 1,460 1,500
  Nom. kW 2.50 2.80 4.00 5.40 5.80 7.00
  Nom. Btu/h 8,500.0 9,500.0 13,600.0 18,400 19,800 23,900
  Nom. kcal/h 2,150.0 2,400.0 3,440.0 4,640 4,990 6,020
  Máx. kW 3.50 4.70 5.20 6.00 6.50 8.00
  Máx. Btu/h 11,900.0 16,000.0 17,700.0 20,500 22,200 27,300
  Máx. kcal/h 3,010.0 4,040.0 4,470.0 5,160 5,590 6,900
Potência absorvida Arrefecimento Mín. kW 0.27 0.27 0.31      
    Nom. kW 0.44 0.56 0.80 1.12 1.36 1.77
    Máx. kW 0.63 0.78 1.04      
  Aquecimento Mín. kW 0.24 0.24 0.32      
    Nom. kW 0.50 0.56 0.99 1.31 1.45 1.94
    Máx. kW 0.91 1.22 1.67      
Eficiência nominal EER   4.57 4.50 4.23 3.75 3.68 3.39
  COP   5.00 5.00 4.04 4.12 4.00 3.61
  Consumo anual de energia kWh 220 (0.000) 280 (0.000) 400 (0.000)      
  Diretiva de etiqueta da energia Arrefecimento   A A A A A A
    Aquecimento   A A A A A A
Eficiência sazonal (de acordo com EN14825) Arrefecimento Classe de eficiência energética   A+++ A+++ A+++ A++ A++ A++
    Pdesign kW 2.00 2.50 3.40 4.20 5.00 6.00
    SEER   8.53 8.52 8.51 7.50 7.33 6.90
    Consumo anual de energia kWh 83 103 140 196 239 304
    Condição A (35°C - 27/19) Pdc kW 2.00 2.50 3.40 4.20 5.00 6.00
      EERd   4.57 4.50 4.23 3.75 3.68 3.39
      potência nominal kW 0.44 0.56 0.80 1.12 1.36 1.77
    Condição B (30℃ - 27/19) Pdc kW 1.47 1.84 2.51 3.09 3.68 4.42
      EERd   6.85 6.42 6.08 5.48 5.51 4.87
      potência nominal kW 0.21 0.29 0.41 0.56 0.67 0.91
    Condição C (25℃ - 27/19) Pdc kW 0.95 1.18 1.61 1.99 2.37 2.84
      EERd   10.73 10.70 10.28 9.30 8.22 8.07
      potência nominal kW 0.09 0.11 0.16 0.21 0.29 0.35
    Condição D (20℃ - 27/19) Pdc kW 0.96 0.96 1.18 1.87 2.12 2.39
      EERd   14.56 14.68 16.50 13.12 14.43 13.64
      potência nominal kW 0.07 0.07 0.07 0.14 0.15 0.18
  Aquecimento (Clima médio) Classe de eficiência energética   A+++ A+++ A+++ A++ A++ A+
    Pdesign kW 2.30 2.40 2.50 4.00 4.60 4.60
    SCOP   5.10 5.10 5.10 4.60 4.60 4.30
    SCOPnet   5.13 5.13 5.14 4.63 4.63 4.33
    Capacidade de aquecimento Pdh a -10° kW 2.24 2.30 2.35 3.68 4.09 4.09
    Consumo anual de energia kWh 632 659 686 1,216 1,400 1,496
    Tampa resist. apoio necessária em condições de design kW 0.06 0.10 0.15 0.32 0.51 0.51
    TOL Tol (temperatura-limite funcionamento) °C -15 -15 -15 -15 -15 -15
      Pdh (tampa de resistência declarada) kW 2.59 2.59 2.59 3.90 4.12 4.12
      COPd (COP declarado)   2.49 2.49 2.49 2.04 2.16 2.15
      Consumo kW 1.04 1.04 1.04 1.91 1.91 1.92
    TBivalent Tbiv (temperatura bivalente) °C -7 -7 -7 -7 -7 -7
      Pdh (tampa resistência declarada) kW 2.03 2.12 2.21 3.54 4.07 4.07
      COPd (COP declarado)   3.57 3.51 3.50 2.70 2.90 2.67
      Consumo kW 0.57 0.60 0.63 1.31 1.40 1.52
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 2.03 2.12 2.21 3.54 4.07 4.07
      COPd (COP declarado)   3.57 3.51 3.50 2.70 2.90 2.67
      Consumo kW 0.57 0.60 0.63 1.31 1.40 1.52
    Condição B (2℃) Pdh (tampa de resist. declarada) kW 1.24 1.29 1.34 2.15 2.48 2.48
      COPd (COP declarado)   5.10 5.06 5.03 4.71 4.65 4.29
      Consumo kW 0.24 0.25 0.27 0.46 0.53 0.58
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 0.91 0.91 0.95 1.38 1.61 1.61
      COPd (COP declarado)   6.33 6.32 6.43 5.99 5.83 5.64
      Consumo kW 0.14 0.14 0.15 0.23 0.28 0.29
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 1.09 1.09 1.09 1.54 1.36 1.52
      COPd (COP declarado)   8.03 8.03 8.05 7.42 7.07 6.83
      Consumo kW 0.14 0.14 0.14 0.21 0.19 0.22
  Aquecimento (Clima quente) Classe de eficiência energética   A+++ A+++ A+++ A+++ A+++ A+++
    Pdesignh kW 1.24 1.29 1.34 2.15 2.48 2.48
    SCOP   6.12 6.21 6.28 5.93 5.84 5.58
    SCOPnet   6.32 6.41 6.48 6.04 5.93 5.66
    Consumo anual de energia kWh 284 291 300 507 595 622
    Tampa resist. apoio necessária, condições de design kW 0.00 0.00 0.00 0.00 0.00 0.00
    TOL Tol (temperatura-limite funcionamento) °C -15 -15 -15 -15 -15 -15
      Pdh (tampa de resistência declarada) kW 2.59 2.59 2.59 3.90 4.12 4.12
      COPd (COP declarado)   2.49 2.49 2.49 2.04 2.16 2.15
      Consumo kW 1.04 1.04 1.04 1.91 1.91 1.92
    TBivalent Tbiv (temperatura bivalente) °C 2 2 2 2 2 2
      Pdh (tampa de resistê. declarada) kW 1.24 1.29 1.34 2.15 2.48 2.48
      COPd (COP declarado)   5.10 5.06 5.03 4.71 4.65 4.29
      Consumo kW 0.24 0.25 0.27 0.46 0.53 0.58
    Condição B (2℃) Pdh (tampa de resist. declarada) kW 1.24 1.29 1.34 2.15 2.48 2.48
      COPd (COP declarado)   5.10 5.06 5.03 4.71 4.65 4.29
      Consumo kW 0.24 0.25 0.27 0.46 0.53 0.58
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 0.91 0.91 0.95 1.38 1.61 1.61
      COPd (COP declarado)   6.33 6.32 6.43 5.99 5.83 5.64
      Consumo kW 0.14 0.14 0.15 0.23 0.28 0.29
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 1.1 1.1 1.1 1.54 1.36 1.52
      COPd (COP declarado)   8.03 8.03 8.05 7.42 7.07 6.83
      Consumo kW 0.14 0.14 0.14 0.21 0.19 0.22
Pto (Thermostat off) W 12.0 12.0 12.0 12.0 12.0 12.0
Arrefecimento Psb (Arrefecimento no modo standby) W 1.0 1.0 1.0 1.0 1.0 1.0
  Cdc (Arrefecimento de deterioração)   0.25 0.25 0.25 0.25 0.25 0.25
Aquecimento Cdh (Aquecimento de degradação)   0.25 0.25 0.25 0.25 0.25 0.25
Poff (Modo desligado) W 1.0 1.0 1.0 1.0 1.0 1.0
Função de arrefecimento incluída Sim Sim Sim Sim Sim Sim
Função de aquecimento incluída Sim Sim Sim Sim Sim Sim
Clima médio incluído Sim Sim Sim Sim Sim Sim
Estação fria incluída Não Não Não Não Não Não
Estação quente incluída Sim Sim Sim Sim Sim Sim
Logótipo etiqueta ecológica Não Não Não Não Não Não
Eurovent Sound power level outdoor Cooling Nom. dBA 59 59 61 62 62 63
  Nível de potência sonora no interior Arrefecimento Nom. dBA 57 57 60 60 59 60
  Comprimento da tubagem Arrefecimento Condição de medição m 5.0 5.0 5.0 5.0 5.0 5.0
Factor de potência Nominal Arrefecimento % 91.10 (0.000) 93.90 (0.000) 79.90 (0.000) 95.30 (0.000) 94.70 (0.000) 97.40 (0.000)
    Aquecimento % 97.60 (0.000) 98.20 (0.000) 90.00 (0.000) 96.10 (0.000) 96.10 (0.000) 99.20 (0.000)
Current Corrente de funcionamento nominal - 50Hz Arrefecimento A 2.1 2.6 4.4 5.11 6.26 7.90
    Aquecimento A 2.2 2.5 4.8 5.93 6.56 8.50
Notas Consulte o esquema separado para conhecer os dados eléctricos Consulte o esquema separado para conhecer os dados eléctricos Consulte o esquema separado para conhecer os dados eléctricos Consulte o esquema separado para conhecer os dados eléctricos Consulte o esquema separado para conhecer os dados eléctricos Consulte o esquema separado para conhecer os dados eléctricos
  As capacidades de arrefecimento nominais são baseadas em: temp. interior: 27 °CBs, 19 °CBh, temperatura exterior: 35 °CBs, tubagem de fluido frigorigéneo equivalente: 5 m, desnível: 0 m. As capacidades de arrefecimento nominais são baseadas em: temp. interior: 27 °CBs, 19 °CBh, temperatura exterior: 35 °CBs, tubagem de fluido frigorigéneo equivalente: 5 m, desnível: 0 m. As capacidades de arrefecimento nominais são baseadas em: temp. interior: 27 °CBs, 19 °CBh, temperatura exterior: 35 °CBs, tubagem de fluido frigorigéneo equivalente: 5 m, desnível: 0 m. As capacidades de arrefecimento nominais são baseadas em: temp. interior: 27 °CBs, 19 °CBh, temperatura exterior: 35 °CBs, tubagem de fluido frigorigéneo equivalente: 5 m, desnível: 0 m. As capacidades de arrefecimento nominais são baseadas em: temp. interior: 27 °CBs, 19 °CBh, temperatura exterior: 35 °CBs, tubagem de fluido frigorigéneo equivalente: 5 m, desnível: 0 m. As capacidades de arrefecimento nominais são baseadas em: temp. interior: 27 °CBs, 19 °CBh, temperatura exterior: 35 °CBs, tubagem de fluido frigorigéneo equivalente: 5 m, desnível: 0 m.
  As capacidades nominais de aquecimento são baseadas em: temperatura interior: 20°CBs, temperatura exterior: 7°CBs, 6°CBh, tubagem de refrigerante equivalente: 5m, diferença de nível: 0m. As capacidades nominais de aquecimento são baseadas em: temperatura interior: 20°CBs, temperatura exterior: 7°CBs, 6°CBh, tubagem de refrigerante equivalente: 5m, diferença de nível: 0m. As capacidades nominais de aquecimento são baseadas em: temperatura interior: 20°CBs, temperatura exterior: 7°CBs, 6°CBh, tubagem de refrigerante equivalente: 5m, diferença de nível: 0m. As capacidades nominais de aquecimento são baseadas em: temperatura interior: 20°CBs, temperatura exterior: 7°CBs, 6°CBh, tubagem de refrigerante equivalente: 5m, diferença de nível: 0m. As capacidades nominais de aquecimento são baseadas em: temperatura interior: 20°CBs, temperatura exterior: 7°CBs, 6°CBh, tubagem de refrigerante equivalente: 5m, diferença de nível: 0m. As capacidades nominais de aquecimento são baseadas em: temperatura interior: 20°CBs, temperatura exterior: 7°CBs, 6°CBh, tubagem de refrigerante equivalente: 5m, diferença de nível: 0m.