FTXS20K2V1B / RXS20K3V1B FTXS20K2V1B / RXS20K2V1B FTXS25K2V1B / RXS25K3V1B FTXS25K2V1B / RXS25K2V1B FTXS35K2V1B / RXS35K2V1B FTXS42K2V1B / RXS42K2V1B FTXS50K2V1B / RXS50K2V1B
Poff (Modo desligado) W 1.0   1.0   1.0 1.0 1.0
Arrefecimento Psb (Arrefecimento no modo standby) W 1.0   1.0   1.0 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25   0.25   0.25 0.25 0.25
Eurovent Nível de potência sonora no interior Arrefecimento Nom. dBA 58   58   59 59 60
  Sound power level outdoor Cooling Nom. dBA 61   62   63 63 63
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 2.00   2.50   3.50 4.20 5.00
    Consumo anual de energia kWh 123   137   176 223 265
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 5.71   6.37   6.97 6.60 6.60
    Condição D (20℃ - 27/19) Pdc kW 1.91   1.86   2.12 2.17 2.14
      potência nominal kW             0.19
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 9.24   10.14   11.61 10.69 11.10
    Condição C (25℃ - 27/19) potência nominal kW             0.29
      Pdc kW 1.79   1.75   2.03 2.09 2.43
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 7.39   8.14   9.04 8.62 8.31
    Condição A (35°C - 27/19) potência nominal kW             1.51
      Pdc kW 2.00   2.50   3.50 4.20 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.35   4.13   3.87 3.28 3.32
    Condição B (30℃ - 27/19) Pdc kW 1.74   1.84   2.64 3.12 3.68
      potência nominal kW             0.70
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.34   6.59   5.95 5.28 5.28
  Aquecimento (Clima médio) Consumo anual de energia kWh 678   756   1,071 1,371 1,571
    Pdesign kW 2.30   2.50   3.60 4.00 4.60
    Tampa resist. apoio necessária em condições de design kW 0.41   0.45   0.63 0.76 0.86
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A++   A++   A++ A+ A+
    TBivalent Pdh (tampa resistência declarada) kW 2.03   2.21   3.18 3.54 4.07
      Consumo kW             1.72
      Tbiv (temperatura bivalente) °C -7   -7   -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.95   2.82   2.74 2.44 2.36
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 1.56   1.51   1.56 2.43 1.50
      Consumo kW             0.30
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.08   6.07   5.58 5.56 5.05
    TOL Tol (temperatura-limite funcionamento) °C -15   -15   -15 -15 -15
      Pdh (tampa de resistência declarada) kW 1.66   1.80   2.61 2.74 3.23
      Consumo kW             1.62
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.54   2.43   2.37 2.02 1.99
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 2.03   2.21   3.18 3.54 4.07
      Consumo kW             1.72
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.95   2.82   2.74 2.44 2.36
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 1.83   1.76   1.88 2.71 1.81
      Consumo kW             0.30
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.25   7.20   6.88 6.41 6.07
    Condição B (2℃) Consumo kW             0.57
      Pdh (tampa de resist. declarada) kW 1.24   1.35   1.93 2.15 2.53
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.35   5.11   5.35 4.38 4.44
Capacidade de arrefecimento Nom. Btu/h 6,800 (2) 6,800 (3) 8,500 (2) 8,500 (3) 11,900 (2) 14,300 (2) 17,100 (2)
  Mín. kW 1.3 1.3 1.3 1.3 1.4 1.7 1.7
  Nom. kcal/h         3,010 (2) 3,610 (2) 4,300 (2)
  Máx. kW 2.8 2.8 3.2 3.2 4.0 5.0 5.3
  Mín. kcal/h         1,200 1,460 1,460
  Mín. Btu/h 4,400 4,400 4,400 4,400 4,800 5,800 5,800
  Nom. kW 2.0 (2) 2.0 (3) 2.5 (2) 2.5 (3) 3.50 (2) 4.20 (2) 5.00 (2)
  Máx. Btu/h 9,600 9,600 10,900 10,900 13,600 17,100 18,100
  Máx. kcal/h         3,440 4,300 4,560
Pck (Modo aquecedor do cárter) W 0.0   0.0   0.0 0.0 0.0
Eficiência nominal Consumo anual de energia kWh 215 (0.000) 215 (0.000) 285 (0.000) 285 (0.000) 420 (0.000) 590 (0.000) 705 (0.000)
  Diretiva de etiqueta da energia Aquecimento A A A A A A A
  Nominal efficiency-=-Cop 4.65 4.65 4.39 4.39 4.17 3.56 3.55
Aquecimento Heating-=-Heating cdh degradation heating 0.25   0.25   0.25 0.25 0.25
Ligações de tubagens Liquid OD mm 6.35 6.35 6.35 6.35 6.35 6.35 6.35
  Gás OD mm 9.5 9.5 9.5 9.5 9.5 9.5 12.7
  Esgoto OD mm 18.0 18.0 18.0 18.0 18 18 18
  Isolamento de calor Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás
Capacidade de aquecimento Mín. Btu/h 4,400 4,400 4,400 4,400 4,800 5,800 5,800
  Nom. Btu/h 8,500 (3) 8,500 (4) 9,600 (3) 9,600 (4) 13,600 (3) 18,400 (3) 19,800 (3)
  Máx. kcal/h         4,470 5,160 5,590
  Máx. Btu/h 14,700 14,700 16,000 16,000 17,700 20,500 22,200
  Nom. kW 2.5 (3) 2.5 (4) 2.8 (3) 2.8 (4) 4.00 (3) 5.40 (3) 5.8 (3)
  Mín. kW 1.3 1.3 1.3 1.3 1.4 1.7 1.7
  Nom. kcal/h         3,440 (3) 4,640 (3) 4,990 (3)
  Mín. kcal/h         1,200 1,460 1,460
  Máx. kW 4.3 4.3 4.7 4.7 5.2 6.0 6.5
Pto (Thermostat off) W 50.0   50.0   40.0 40.0 50.0
Potência absorvida Arrefecimento Mín. kW 0.320 0.320 0.320 0.320 0.350 0.320 0.350
    Nom. kW 0.430 0.430 0.570 0.570 0.840 1.180 1.410
    Máx. kW 0.760 0.760 1.000 1.000 1.190 2.330 1.810
  Aquecimento Máx. kW 1.120 1.120 1.410 1.410 1.460 1.980 2.000
    Mín. kW 0.310 0.310 0.310 0.310 0.340 0.400 0.300
    Nom. kW 0.550 0.550 0.620 0.620 0.840 1.310 1.450
Estação fria incluída Sim   Sim   Sim Sim Sim
Current Corrente de funcionamento nominal - 50Hz Aquecimento A 2.8 (4), 2.7 (5), 2.6 (6) 2.8 (5), 2.7 (6), 2.6 (7) 3.3 (4), 3.2 (5), 3.1 (6) 3.3 (5), 3.2 (6), 3.1 (7) 4.3 (4), 4.1 (5), 3.9 (6) 6.6 (4), 6.3 (5), 6.0 (6) 6.8 (4), 6.5 (5), 6.2 (6)
    Arrefecimento A 2.4 (4), 2.3 (5), 2.2 (6) 2.4 (5), 2.3 (6), 2.2 (7) 3.2 (4), 3.1 (5), 3.0 (6) 3.2 (5), 3.1 (6), 3.0 (7) 4.3 (4), 4.1 (5), 3.9 (6) 6.0 (4), 5.7 (5), 5.5 (6) 6.6 (4), 6.3 (5), 6.0 (6)
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE Etiqueta energética: escala de A (mais eficiente) a G (menos eficiente) EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE Etiqueta energética: escala de A (mais eficiente) a G (menos eficiente) EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; comprimento de tubagem equivalente: 5m Consumo anual de energia: baseado na utilização média de 500 horas de funcionamento por ano em plena carga (condições nominais) Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; comprimento de tubagem equivalente: 5m Consumo anual de energia: baseado na utilização média de 500 horas de funcionamento por ano em plena carga (condições nominais) Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m
  Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m
  220V Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m 220V Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m 220V 220V 220V
  230V 220V 230V 220V 230V 230V 230V
  240V 230V 240V 230V 240V 240V 240V
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal 240V Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal 240V Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal
    Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal   Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal