FTXS20K2V1B / RXS20L2V1B FTXS25K2V1B / RXS25L2V1B FTXS35K2V1B / RXS35L2V1B FTXS42K2V1B / RXS42L2V1B FTXS42K3V1B / RXS42L2V1B FTXS50K2V1B / RXS50L2V1B FTXS50K3V1B / RXS50L2V1B
Poff (Modo desligado) W 1.0 1.0 1.0 1.0 1.0 1.0 1.0
Arrefecimento Psb (Arrefecimento no modo standby) W 1.0 1.0 1.0 1.0 1.0 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25 0.25 0.25 0.25 0.25
Remoção de humidade Arrefecimento l/h         2.3   2.8
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 2.00 2.50 3.50 4.20 4.20 5.00 5.00
    Consumo anual de energia kWh 95 111 164 216 216 257 257
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 7.40 7.90 7.47 6.80 6.80 6.80 6.80
    Condição D (20℃ - 27/19) Pdc kW 1.29 1.28 1.46 2.17 2.17 2.14 2.14
      potência nominal kW         0.20   0.19
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 11.65 12.71 12.51 10.69 10.69 11.10 11.10
    Condição C (25℃ - 27/19) potência nominal kW         0.24   0.29
      Pdc kW 1.22 1.22 1.66 2.09 2.09 2.43 2.43
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 9.32 9.98 9.17 8.80 8.80 8.48 8.48
    Condição A (35°C - 27/19) potência nominal kW         1.25   1.51
      Pdc kW 2.00 2.50 3.50 4.20 4.20 5.00 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.39 4.21 3.89 3.35 3.35 3.32 3.32
    Condição B (30℃ - 27/19) Pdc kW 1.47 1.84 2.58 3.09 3.09 3.68 3.68
      potência nominal kW         0.56   0.68
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.99 6.71 6.10 5.47 5.47 5.38 5.38
  Aquecimento (Clima médio) Consumo anual de energia kWh 675 732 1,039 1,334 1,334 1,535 1,535
    Pdesign kW 2.30 2.50 3.60 4.00 4.00 4.60 4.60
    Tampa resist. apoio necessária em condições de design kW 0.11 0.15 0.55 0.32 0.32 0.52 0.52
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A++ A++ A++ A+ A+ A+ A+
    TBivalent Pdh (tampa resistência declarada) kW 2.03 2.21 3.18 3.54 3.54 4.07 4.07
      Consumo kW         1.45   1.72
      Tbiv (temperatura bivalente) °C -7 -7 -7 -7 -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 3.10 3.10 2.85 2.44 2.44 2.36 2.36
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 0.99 1.00 1.25 1.66 1.66 1.62 1.62
      Consumo kW         0.30   0.30
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.96 5.96 6.42 5.59 5.59 5.35 5.35
    TOL Tol (temperatura-limite funcionamento) °C -15 -15 -15 -15 -15 -15 -15
      Pdh (tampa de resistência declarada) kW 2.47 2.59 2.84 3.90 3.90 4.11 4.11
      Consumo kW         1.91   1.94
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.52 2.50 2.33 2.04 2.04 2.12 2.12
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 2.03 2.21 3.18 3.54 3.54 4.07 4.07
      Consumo kW         1.45   1.72
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 3.10 3.10 2.85 2.44 2.44 2.36 2.36
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 1.32 1.34 1.09 1.84 1.84 1.95 1.95
      Consumo kW         0.28   0.30
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.10 7.10 7.79 6.59 6.59 6.43 6.43
    Condição B (2℃) Consumo kW         0.49   0.56
      Pdh (tampa de resist. declarada) kW 1.23 1.35 1.95 2.15 2.15 2.48 2.48
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.00 5.00 4.95 4.38 4.38 4.44 4.44
Capacidade de arrefecimento Nom. Btu/h 6,800 8,500 11,900 14,300 14,300 (2) 17,100 17,100 (2)
  Mín. kW 1.3 1.3 1.4 1.7 1.7 1.7 1.7
  Nom. kcal/h 1,720 2,150 3,010 3,610 3,610 (2) 4,300 4,300 (2)
  Máx. kW 2.8 3.2 4.0 5.0 5.0 5.3 5.3
  Mín. kcal/h 1,120 1,120 1,200 1,460 1,460 1,460 1,460
  Mín. Btu/h 4,400 4,400 4,800 5,800 5,800 5,800 5,800
  Nom. kW 2.00 2.5 3.5 4.20 4.20 (2) 5.00 5.00 (2)
  Máx. Btu/h 9,600 10,900 13,600 17,100 17,100 18,100 18,100
  Máx. kcal/h 2,410 2,750 3,440 4,300 4,300 4,560 4,560
Pck (Modo aquecedor do cárter) W 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Eficiência nominal Consumo anual de energia kWh 215 (0.000) 285 (0.000) 430 (0.000) 590 (0.000) 627 (0.000) 705 (0.000) 753 (0.000)
  Diretiva de etiqueta da energia Aquecimento A A A A A A A
  Nominal efficiency-=-Cop 4.65 4.39 4.07 3.56 3.35 (1) 3.55 3.32 (1)
Aquecimento Heating-=-Heating cdh degradation heating 0.25 0.25 0.25 0.25 0.25 0.25 0.25
Ligações de tubagens Liquid OD mm 6.35 6.35 6.35 6.35 6.35 6.35 6.35
  Gás OD mm 9.5 9.5 9.5 9.5 12.7 12.7 12.7
  Esgoto OD mm 18 18 18 18 18 18 18
  Isolamento de calor Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás
Capacidade de aquecimento Mín. Btu/h 4,400 4,400 4,800 5,800 5,800 5,800 5,800
  Nom. Btu/h 8,500 9,600 13,600 18,400 18,400 (2) 19,800 19,800 (2)
  Máx. kcal/h 3,700 4,040 4,470 5,160 5,160 5,590 5,590
  Máx. Btu/h 14,700 16,000 17,700 20,500 20,500 22,200 22,200
  Nom. kW 2.5 2.8 4.00 5.40 5.40 (2) 5.80 5.80 (2)
  Mín. kW 1.3 1.3 1.4 1.7 1.7 1.7 1.7
  Nom. kcal/h 2,150 2,410 3,440 4,640 4,640 (2) 4,990 4,990 (2)
  Mín. kcal/h 1,120 1,120 1,200 1,460 1,460 1,460 1,460
  Máx. kW 4.3 4.7 5.2 6.0 6.0 6.5 6.5
Pto (Thermostat off) W 20.0 21.0 28.0 30.0 30.0 30.0 30.0
Potência absorvida Arrefecimento Mín. kW 0.320 0.320 0.350 0.320 0.320 0.350 0.350
    Nom. kW 0.430 0.570 0.860 1.180 1.253 (2) 1.410 1.506 (2)
    Máx. kW 0.760 1.000 1.190 2.330 2.330 1.810 1.810
  Aquecimento Máx. kW 1.120 1.410 1.460 1.980 1.980 2.000 2.000
    Mín. kW 0.310 0.310 0.340 0.400 0.400 0.300 0.300
    Nom. kW 0.530 0.600 0.840 1.310 1.310 (2) 1.450 1.450 (2)
Estação fria incluída Sim Sim Sim Sim Sim Sim Sim
Current Corrente de funcionamento nominal - 50Hz Aquecimento A 2.8 (2), 2.7 (3), 2.6 (4) 3.3 (2), 3.2 (3), 3.1 (4) 4.3 (2), 4.1 (3), 3.9 (4) 6.6 (2), 6.3 (3), 6.0 (4) 6.6 (3), 6.3 (4), 6.0 (5) 6.8 (2), 6.5 (3), 6.2 (4) 6.8 (3), 6.5 (4), 6.2 (5)
    Arrefecimento A 2.4 (2), 2.3 (3), 2.2 (4) 3.2 (2), 3.1 (3), 3.0 (4) 4.3 (2), 4.1 (3), 3.9 (4) 6.0 (2), 5.7 (3), 5.5 (4) 6.37 (3), 6.05 (4), 5.84 (5) 6.6 (2), 6.3 (3), 6.0 (4) 7.05 (3), 6.73 (4), 6.41 (5)
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  220V 220V 220V 220V Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal 220V Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal
  230V 230V 230V 230V 220V 230V 220V
  240V 240V 240V 240V 230V 240V 230V
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal 240V Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal 240V