Dados Técnicos para FTXZ-N / RXZ-N

FTXZ25NV1B / RXZ25NV1B FTXZ35NV1B / RXZ35NV1B FTXZ50NV1B / RXZ50NV1B
Poff (Modo desligado) W 1.0 1.0 1.0
Arrefecimento Psb (Arrefecimento no modo standby) W 1.0 1.0 1.0
  Cooling-=-Cooling cdc degradation cooling 0.25 0.25 0.25
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 2.50 3.50 5.00
    Consumo anual de energia kWh 92 136 203
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 9.54 9.00 8.60
    Condição D (20℃ - 27/19) Pdc kW 1.68 1.63 2.36
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 12.36 10.70 12.04
    Condição C (25℃ - 27/19) Pdc kW 1.53 1.66 2.38
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 12.23 11.86 11.22
    Condição A (35°C - 27/19) Pdc kW 2.50 3.50 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 6.18 5.27 4.36
    Condição B (30℃ - 27/19) Pdc kW 1.84 2.58 3.71
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 8.92 7.66 6.69
  Aquecimento (Clima médio) Consumo anual de energia kWh 831 1,100 1,427
    Pdesign kW 3.50 4.50 5.60
    Tampa resist. apoio necessária em condições de design kW 0.66 0.91 1.02
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A+++ A+++ A+++
    TBivalent Pdh (tampa resistência declarada) kW 3.10 3.98 4.95
      Tbiv (temperatura bivalente) °C -7 -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 4.10 3.91 3.82
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 1.21 1.56 1.94
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 7.56 7.45 7.25
    TOL Tol (temperatura-limite funcionamento) °C -15 -15 -15
      Pdh (tampa de resistência declarada) kW 2.41 2.94 3.97
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 3.18 3.25 2.98
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 3.10 3.98 4.95
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 4.10 3.91 3.82
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 0.79 0.69 0.91
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 8.30 8.09 6.33
    Condição B (2℃) Pdh (tampa de resist. declarada) kW 1.88 2.42 3.02
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 5.81 5.57 5.42
Capacidade de arrefecimento Nom. Btu/h 8,500 11,900 17,100
  Mín. kW 0.6 0.6 0.6
  Nom. kcal/h 2,150 3,010 4,300
  Máx. kW 3.9 5.3 5.8
  Mín. kcal/h 520 520 520
  Mín. Btu/h 2,000 2,000 2,000
  Nom. kW 2.5 3.5 5.0
  Máx. Btu/h 13,100 18,100 19,400
  Máx. kcal/h 3,350 4,560 4,990
Pck (Modo aquecedor do cárter) W 0.0 0.0 0.0
Eficiência nominal Annual energy consumption kWh 205 (0.000) 330 (0.000) 550 (0.000)
  Diretiva de etiqueta da energia Aquecimento A A A
  Nominal efficiency-=-Cop 6.10 (1) 5.30 (1) 4.55 (1)
Aquecimento Heating-=-Heating cdh degradation heating 0.25 0.25 0.25
Ligações de tubagens Liquid OD mm 6.35 6.35 6.35
  Gás OD mm 9.5 9.5 9.5
Capacidade de aquecimento Mín. Btu/h 2,000 2,000 2,000
  Nom. Btu/h 9,600 17,100 21,500
  Máx. kcal/h 6,450 7,740 8,080
  Máx. Btu/h 25,500 30,700 32,000
  Nom. kW 3.6 5.0 6.3
  Mín. kW 0.6 0.6 0.6
  Nom. kcal/h 2,150 2,150 5,420
  Mín. kcal/h 520 520 520
  Máx. kW 7.5 9.0 9.4
Pto (Thermostat off) W 6.0 6.0 6.0
Potência nominal Arrefecimento Mín. kW 0.11 0.11 0.11
    Nom. kW 0.41 0.66 1.10
    Máx. kW 0.88 1.33 1.60
  Aquecimento Máx. kW 2.01 2.53 2.64
    Mín. kW 0.10 0.10 0.10
    Nom. kW 0.62 1.00 1.41
Estação fria incluída Sim Sim Sim
Corrente Corrente de funcionamento nominal - 50Hz Aquecimento A 2.9 (3), 2.8 (4), 2.7 (5) 4.6 (3), 4.4 (4), 4.3 (5) 6.5 (3), 6.2 (4), 6.0 (5)
    Arrefecimento A 2.0 (3), 1.9 (4), 1.9 (5) 3.1 (3), 2.9 (4), 2.8 (5) 5.1 (3), 4.9 (4), 4.6 (5)
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal
  220V 220V 220V
  230V 230V 230V
  240V 240V 240V