FVXG25K2V1B / RXLG25K3V1B FVXG25K2V1B / RXLG25K2V1B FVXG35K2V1B / RXLG35K3V1B FVXG35K2V1B / RXLG35K2V1B FVXG50K2V1B / RXLG50K3V1B FVXG50K2V1B / RXLG50K2V1B
Poff (Modo desligado) W 1.0   1.0   20.0  
Arrefecimento Psb (Arrefecimento no modo standby) W 1.0   1.0   20.0  
  Cooling-=-Cooling cdc degradation cooling 0.25   0.25   0.25  
Eurovent Nível de potência sonora no interior Arrefecimento Nom. dBA           58
  Sound power level outdoor Cooling Nom. dBA           63
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 2.50   3.50   5.00  
    Consumo anual de energia kWh 135   194   330  
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 6.46   6.33   5.31  
    Condição D (20℃ - 27/19) Pdc kW 1.87   1.89   2.12  
      potência nominal kW 0.18   0.18   0.20  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.49   10.24   10.41  
    Condição C (25℃ - 27/19) potência nominal kW 0.21   0.22   0.32  
      Pdc kW 1.76   1.80   2.37  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.42   8.09   7.43  
    Condição A (35°C - 27/19) potência nominal kW 0.58   0.99   1.61  
      Pdc kW 2.50   3.50   5.00  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.29   3.52   3.11  
    Condição B (30℃ - 27/19) Pdc kW 1.84   2.58   3.68  
      potência nominal kW 0.27   0.46   0.74  
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.82   5.58   4.94  
  Aquecimento (Clima médio) Consumo anual de energia kWh 877   1,122   1,577  
    Pdesign kW 2.80   3.10   4.60  
    Tampa resist. apoio necessária em condições de design kW 0.51   0.61   0.86  
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A+   A   A+  
    TBivalent Pdh (tampa resistência declarada) kW 2.48   2.74   4.07  
      Consumo kW 1.03   1.28   1.82  
      Tbiv (temperatura bivalente) °C -7   -7   -7  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.40   2.14   2.23  
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 1.45   1.36   1.62  
      Consumo kW 0.24   0.26   0.30  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 6.10   5.13   5.37  
    TOL Tol (temperatura-limite funcionamento) °C -25   -25   -25  
      Pdh (tampa de resistência declarada) kW 1.38   1.29   2.18  
      Consumo kW 0.90   1.15   2.16  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 1.53   1.12   1.01  
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 2.48   2.74   4.07  
      Consumo kW 1.03   1.28   1.82  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.40   2.14   2.23  
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 1.69   1.59   1.90  
      Consumo kW 0.23   0.25   0.29  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 7.24   6.25   6.60  
    Condição B (2℃) Consumo kW 0.30   0.40   0.57  
      Pdh (tampa de resist. declarada) kW 1.51   1.66   2.47  
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.95   4.20   4.34  
Capacidade de arrefecimento Nom. Btu/h 8,500 (2)   11,900 (2)   17,100 (2) 17,100 (2)
  Mín. kW 1.3 1.3 1.4 1.4 1.7 1.7
  Nom. kcal/h 2,150 (2)   3,010 (2)   4,300 (2) 4,300 (2)
  Máx. kW 3.0 3.0 3.8 3.8 5.6 5.6
  Mín. kcal/h 1,120   1,200   1,460 1,460
  Mín. Btu/h 4,400   4,800   5,800 5,800
  Nom. kW 2.5 (2) 2.5 (3) 3.5 (2) 3.5 (3) 5.0 (2) 5.0 (2)
  Máx. Btu/h 10,200   13,000   19,100 19,100
  Máx. kcal/h 2,580   3,270   4,820 4,820
Pck (Modo aquecedor do cárter) W 0.0   0.0   0.0  
Eficiência nominal Consumo anual de energia kWh 275 (0.000) 275 (0.000) 475 (0.000) 476 (0.000) 760 (0.000) 760 (0.000)
  Diretiva de etiqueta da energia Aquecimento A A A A A A
  Nominal efficiency-=-Cop 4.55 4.55 3.68 3.68 3.29 (1) 3.29 (1)
Aquecimento Heating-=-Heating cdh degradation heating 0.25   0.25   0.25  
Ligações de tubagens Liquid OD mm 6.35 6.35 6.35 6.35 6.35 6.35
  Gás OD mm 9.5 9.5 9.5 9.5 12.7 12.7
  Esgoto OD mm 18.0   18.0   18.0 18.0
  Isolamento de calor Tubos de líquidos e gás   Tubos de líquidos e gás   Tubos de líquidos e gás Tubos de líquidos e gás
Capacidade de aquecimento Mín. Btu/h 4,400   4,800   5,800 5,800
  Nom. Btu/h 11,600 (3)   15,400 (3)   19,800 (3) 19,800 (3)
  Máx. kcal/h 3,870   4,300   6,970 6,970
  Máx. Btu/h 15,400   17,100   27,600 27,600
  Nom. kW 3.4 (3) 3.4 (4) 4.5 (3) 4.5 (4) 5.8 (3) 5.8 (3)
  Mín. kW 1.3 1.3 1.4 1.4 1.7 1.7
  Nom. kcal/h 2,920 (3)   3,870 (3)   4,990 (3) 4,990 (3)
  Mín. kcal/h 1,120   1,200   1,460 1,460
  Máx. kW 4.5 4.5 5.0 5.0 8.1 8.1
Pto (Thermostat off) W 60.0   60.0   60.0  
Potência absorvida Arrefecimento Mín. kW 0.300   0.310   0.450 0.450
    Nom. kW 0.550 0.55 0.950 0.95 1.520 1.520 (2)
    Máx. kW 0.790   1.150   2.000 2.000
  Aquecimento Máx. kW 1.270   1.460   2.660 2.660
    Mín. kW 0.290   0.290   0.500 0.500
    Nom. kW 0.780 0.78 1.210 1.21 1.580 1.580 (3)
Estação fria incluída Sim   Sim   Sim  
Current Corrente de funcionamento nominal - 50Hz Aquecimento A 4.1 (4), 3.9 (5), 3.7 (6)   6.0 (4), 5.7 (5), 5.5 (6)   7.3 (4), 7.0 (5), 6.7 (6) 7.3 (4), 7.0 (5), 6.7 (6)
    Arrefecimento A 3.0 (4), 2.9 (5), 2.8 (6)   4.8 (4), 4.6 (5), 4.4 (6)   7.1 (4), 6.7 (5), 6.5 (6) 7.1 (4), 6.7 (5), 6.5 (6)
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE Etiqueta energética: escala de A (mais eficiente) a G (menos eficiente) EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE Etiqueta energética: escala de A (mais eficiente) a G (menos eficiente) EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m (horizontal) Consumo anual de energia: baseado na utilização média de 500 horas de funcionamento por ano em plena carga (condições nominais) Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m (horizontal) Consumo anual de energia: baseado na utilização média de 500 horas de funcionamento por ano em plena carga (condições nominais) Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m
  Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m (horizontal) Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m (horizontal) Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m (horizontal) Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m (horizontal) Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m
  220V Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m (horizontal) 220V Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m (horizontal) 220V 220V
  230V Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal 230V Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal 230V 230V
  240V   240V   240V 240V
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal   Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal   Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal