FVXS25FV1B / RXS25K3V1B FVXS25FV1B / RXS25K2V1B FVXS35FV1B / RXS35K2V1B FVXS50FV1B / RXS50K2V1B
Poff (Modo desligado) W 20.0   20.0 20.0
Arrefecimento Psb (Arrefecimento no modo standby) W 20.0   20.0 20.0
  Cooling-=-Cooling cdc degradation cooling 0.25   0.25 0.25
Eficiência sazonal (de acordo com EN14825) Arrefecimento Pdesign kW 2.50   3.50 5.00
    Consumo anual de energia kWh 186   248 317
    Seasonal efficiency (according to EN14825)-=-Cooling-=-Seasonal efficiency according to en14825 cooling energy efficiency class 4.71   4.93 5.53
    Condição D (20℃ - 27/19) Pdc kW 1.84   1.80 2.23
      potência nominal kW       0.20
      Seasonal efficiency (according to EN14825)-=-Cooling-=-D Condition (20°C - 27/19)-=-Eerd 10.08   9.83 10.90
    Condição C (25℃ - 27/19) potência nominal kW       0.30
      Pdc kW 1.73   1.71 2.37
      Seasonal efficiency (according to EN14825)-=-Cooling-=-C Condition (25°C - 27/19)-=-Eerd 8.10   7.73 7.96
    Condição A (35°C - 27/19) potência nominal kW       1.47
      Pdc kW 2.50   3.50 5.00
      Seasonal efficiency (according to EN14825)-=-Cooling-=-A Condition (35°C - 27/19)-=-Eerd 4.08   3.27 3.40
    Condição B (30℃ - 27/19) Pdc kW 1.84   2.58 3.69
      potência nominal kW       0.70
      Seasonal efficiency (according to EN14825)-=-Cooling-=-B Condition (30°C - 27/19)-=-Eerd 6.50   5.21 5.29
  Aquecimento (Clima médio) Consumo anual de energia kWh 830   1,060 1,853
    Pdesign kW 2.60   2.90 4.80
    Tampa resist. apoio necessária em condições de design kW 0.48   0.57 0.86
    Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-Seasonal efficiency according to en14825 heating average climate scop a A+   A A
    TBivalent Pdh (tampa resistência declarada) kW 2.30   2.57 4.25
      Consumo kW       2.04
      Tbiv (temperatura bivalente) °C -7   -7 -7
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TBivalent-=-Copd declared cop 2.65   2.33 2.08
    Condição C (7℃) Pdh (tampa de resist. declarada) kW 1.42   1.35 1.67
      Consumo kW       0.35
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-C Condition (7°C)-=-Copd declared cop 5.85   5.02 4.75
    TOL Tol (temperatura-limite funcionamento) °C -15   -15 -15
      Pdh (tampa de resistência declarada) kW 1.82   1.93 3.43
      Consumo kW       1.93
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-TOL-=-Copd declared cop 2.23   1.89 1.78
    Condição A (-7°C) Pdh (tampa de resist. declarada) kW 2.30   2.57 4.25
      Consumo kW       2.04
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-A Condition (-7°C)-=-Copd declared cop 2.65   2.33 2.08
    Condição D (12℃) Pdh (tampa de resist. declarada) kW 1.66   1.58 1.80
      Consumo kW       0.31
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-D Condition (12°C)-=-Copd declared cop 6.95   6.10 5.82
    Condição B (2℃) Consumo kW       0.69
      Pdh (tampa de resist. declarada) kW 1.41   1.56 2.59
      Seasonal efficiency (according to EN14825)-=-Heating (Average climate)-=-B Condition (2°C)-=-Copd declared cop 4.80   4.11 3.77
Capacidade de arrefecimento Nom. Btu/h 8,500 (2) 8,500 (3) 11,900 (2) 17,100 (2)
  Mín. kW 1.3 1.3 1.4 1.4
  Nom. kcal/h 2,150 (2) 2,150 (3) 3,010 (2) 4,300 (2)
  Máx. kW 3.0 3.0 3.8 5.6
  Mín. kcal/h 1,120 1,120 1,200 1,200
  Mín. Btu/h 4,400 4,400 4,800 4,800
  Nom. kW 2.5 (2) 2.5 (3) 3.5 (2) 5.0 (2)
  Máx. Btu/h 10,200 10,200 13,000 19,100
  Máx. kcal/h 2,580 2,580 3,270 4,820
Pck (Modo aquecedor do cárter) W 0.0   0.0 0.0
Eficiência nominal Annual energy consumption kWh 285 (0.000) 285 (0.000) 510 (0.000) 775 (0.000)
  Diretiva de etiqueta da energia Aquecimento A A A A
  Nominal efficiency-=-Cop 4.39 4.39 3.43 3.23
Aquecimento Heating-=-Heating cdh degradation heating 0.25   0.25 0.25
Ligações de tubagens Liquid OD mm 6.35 6.35 6.35 6.35
  Gás OD mm 9.5 9.5 9.5 12.7
  Esgoto OD mm 20.0 20 20.0 20.0
  Isolamento de calor Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás Tubos de líquidos e gás
Capacidade de aquecimento Mín. Btu/h 4,400 4,400 4,800 4,800
  Nom. Btu/h 11,600 (3) 11,600 (4) 15,400 (3) 19,800 (3)
  Máx. kcal/h 3,870 4,300 4,300 6,970
  Máx. Btu/h 15,400 17,100 17,100 27,600
  Nom. kW 3.4 (3) 3.4 (4) 4.5 (3) 5.8 (3)
  Mín. kW 1.3 1.3 1.4 1.4
  Nom. kcal/h 2,920 (3) 2,920 (4) 3,870 (3) 4,990 (3)
  Mín. kcal/h 1,120 1,120 1,200 1,200
  Máx. kW 4.5 4.5 5.0 8.1
Pto (Thermostat off) W 80.0   80.0 80.0
Potência nominal Arrefecimento Mín. kW 0.300 0.300 0.300 0.500
    Nom. kW 0.570 0.570 1.020 1.550
    Máx. kW 0.920 0.920 1.250 2.000
  Aquecimento Máx. kW 1.390 1.390 1.880 2.600
    Mín. kW 0.290 0.290 0.310 0.500
    Nom. kW 0.790 0.790 1.220 1.600
Estação fria incluída Sim   Sim Sim
Corrente Corrente de funcionamento nominal - 50Hz Aquecimento A 4.5 (4), 4.3 (5), 4.1 (6) 4.5 (5), 4.3 (6), 4.1 (7) 5.9 (4), 5.6 (5), 5.4 (6) 7.3 (4), 7.0 (5), 6.7 (6)
    Arrefecimento A 3.5 (4), 3.3 (5), 3.2 (6) 3.5 (5), 3.3 (6), 3.2 (7) 4.9 (4), 4.7 (5), 4.5 (6) 7.2 (4), 6.8 (5), 6.6 (6)
Notas EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE Etiqueta energética: escala de A (mais eficiente) a G (menos eficiente) EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE EER/COP de acordo com Eurovent 2012, para utilização exclusivamente fora da UE
  Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; comprimento de tubagem equivalente: 5m; desnível: 0m Consumo anual de energia: baseado na utilização média de 500 horas de funcionamento por ano em plena carga (condições nominais) Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; 24°CBh; comprimento equivalente de tubagem: 5m
  Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m; desnível: 0m Arrefecimento: temp. interior: 27°CBs, 19,0°CBh; temp. exterior 35°CBs; comprimento de tubagem equivalente: 5m; desnível: 0m Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m
  220V Aquecimento: temp. interior: 20°CBs; temp. exterior 7°CBs, 6°CBh; tubagem de refrigerante equivalente: 5m; desnível: 0m 220V 220V
  230V 220V 230V 230V
  240V 230V 240V 240V
  Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal 240V Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal
    Eficiência nominal: arrefecimento a 35°/27° de carga nominal, aquecimento a 7°/20° de carga nominal